2001
DOI: 10.1002/jlcr.478
|View full text |Cite
|
Sign up to set email alerts
|

Labelling of octreotide using 76Br‐prosthetic groups

Abstract: SummaryA method for labelling the octapeptide octreotide (d^Phe-Cys-Phe-d-TrpLys-Thr-Cys-Thr(ol)) with the positron emitting 76 Br (T 1=2 =16 h) ispresented.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2002
2002
2017
2017

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 21 publications
(13 reference statements)
0
3
0
1
Order By: Relevance
“…The use of positron-emitting halogen radionuclides, specifically 124 I (t 1/2 ) 4.2 d) and 76 Br (t 1/2 ) 16 h), to label radiopharmaceuticals for PET imaging has increased greatly over the past decade. For example, 76 Br has been labeled to octreotide (5) and 76 Br-labeled bromodeoxyuridine has been investigated as a tumor and brain imaging agent (6,7). Iodine-124 is currently used to produce [ 124 I]-5-iodo-2′-fluoro-1-β-D-arabinofuranosyl-uracil (FIAU) which has been used to image gene expression (8).…”
Section: Introductionmentioning
confidence: 99%
“…The use of positron-emitting halogen radionuclides, specifically 124 I (t 1/2 ) 4.2 d) and 76 Br (t 1/2 ) 16 h), to label radiopharmaceuticals for PET imaging has increased greatly over the past decade. For example, 76 Br has been labeled to octreotide (5) and 76 Br-labeled bromodeoxyuridine has been investigated as a tumor and brain imaging agent (6,7). Iodine-124 is currently used to produce [ 124 I]-5-iodo-2′-fluoro-1-β-D-arabinofuranosyl-uracil (FIAU) which has been used to image gene expression (8).…”
Section: Introductionmentioning
confidence: 99%
“…The only significant contribution to the total activity 16 hours post EOB is due to 76 Br. There is < 1% 75 Br and 77 Br Numerous preparations of lower specific activity radiobrominated pharmaceuticals are reported in the literature [16][17][18][19][20]. The low SA is due to carrier bromide present in the target material, reagents, or solvents.…”
Section: Resultsmentioning
confidence: 99%
“…Реактивы и растворители получены от компании «Enamin». Метил арилкарбоксиимидаты (5а-е) получены по стандарт-ным методикам и использовались без очистки [13]. Общая методика получения 5-(3-аминофенил)-2,4-дигидро-3H-1,2,4-триазол-3-онов (8a, b).…”
Section: экспериментальная частьunclassified