Laboratory control of minimal heparinization during haemodialysis in patients with a risk of haemorrhage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0
1

Year Published

1997
1997
2006
2006

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 0 publications
0
12
0
1
Order By: Relevance
“…A variation of 620% above normal was regarded as pathological change of the respective parameter. The area under the curve (AUC) versus time of dialysis represents the appropriate parameter for the assessment of hemocompatibility parameters, as were the generation of procoagulatory molecular markers during time of dialysis and were calculated as previously described [9,11]. The statistical significance was defined as p !…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A variation of 620% above normal was regarded as pathological change of the respective parameter. The area under the curve (AUC) versus time of dialysis represents the appropriate parameter for the assessment of hemocompatibility parameters, as were the generation of procoagulatory molecular markers during time of dialysis and were calculated as previously described [9,11]. The statistical significance was defined as p !…”
Section: Discussionmentioning
confidence: 99%
“…Blood samples to determine anti-Xa activity and TAT were taken from the arterial and venous blood line before the enoxaparin bolus, after 15 min, at 2 h, and at the end of HD. Median and mean duration of dialysis sessions was 4 h. Anti-Xa activity was determined with Coatest ® LMW Heparin/Heparin (Chromogenix, Monza, Italy) and TAT with the Enzygnost ® TAT micro (Behringwerke AG, Marburg, Germany) following the manufacturer's instructions and as otherwise described [9,10].…”
Section: Molecular Characterization Of Enoxaparin Anticoagulationmentioning
confidence: 99%
“…We excluded 114 studies after title and abstract screening using inclusion and exclusion criteria. Of the 33 remaining studies, 15 did not meet the inclusion criteria after article review: 14 studies were not randomized (12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25), and one study used a historical control UFH arm (26). One study was excluded because all patients had underlying hypercoagulability (27).…”
Section: Study Identification and Selectionmentioning
confidence: 99%
“…Mean hematocrit was 0.36 (SEM 0.04). The area under the curve (AUC) of neutrophil elastase and complement factor C3a versus time of dialysis represents the best parameter for the generation of each factor during time of dialysis and was calculated as described before [18].…”
Section: Blood Sampling and Laboratory Parametersmentioning
confidence: 99%
“…AUC of both parameters can be regarded as suitable hemocompatibility markers superior to the comparison of values at single times [18,21]. Irrespective of the higher values of C3a at 15 min, accompanied with the increase of neutrophil elastase, and the more pronounced drop of white blood cells for F-60S, there was no statistically significant difference between the calculated AUC of complement generation or neutrophil elastase release of both dialyzers.…”
Section: Blood Compatibilitymentioning
confidence: 99%