Laparoscopic Repair of Ventral and other hernias of the abdominal wall with Composite meshes (Ventralight ST with Echo PS System and Physiomesh): Our case series of 101 patients and the literature
Abstract:Highlights
The incidence of ventral hernias varies from 4 to 10% depending on the type of surgery.
Careful patient selection is one of the main methods of choice.
Laparoscopic ventral hernia repair with Ventralight ST/Sorbafix is a safe and effective technique with low postoperative morbidity and low reoperation rate.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.