2020
DOI: 10.1016/j.yofte.2020.102153
|View full text |Cite
|
Sign up to set email alerts
|

Large core-offset based in-fiber Michelson interferometer for humidity sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…In last decade, several fiber optic sensors have been realized and reported for temperature sensing. These interferometers include Fiber Brag Grating (FBG) [1][2][3][4], Long-Period Fiber Grating (LPFG) [5][6][7][8], Mode field interferometers [9,10], Mach-Zehnder Interferometers (MZI) [11][12][13][14][15][16], Michelson Interferometers (MI) [17,18], Fabry-Perot Interferometers (FPI) [19][20][21][22][23], Hybrid Interferometers (MZI and FPI) [12,14,24], Interferometer composed of Silicon-on-Insulators (SOI) [25], and Surface Plasma Resonance (SPR) [26]. In these configurations, mostly silica is used as a sensing element for temperature measurement.…”
Section: Introductionmentioning
confidence: 99%
“…In last decade, several fiber optic sensors have been realized and reported for temperature sensing. These interferometers include Fiber Brag Grating (FBG) [1][2][3][4], Long-Period Fiber Grating (LPFG) [5][6][7][8], Mode field interferometers [9,10], Mach-Zehnder Interferometers (MZI) [11][12][13][14][15][16], Michelson Interferometers (MI) [17,18], Fabry-Perot Interferometers (FPI) [19][20][21][22][23], Hybrid Interferometers (MZI and FPI) [12,14,24], Interferometer composed of Silicon-on-Insulators (SOI) [25], and Surface Plasma Resonance (SPR) [26]. In these configurations, mostly silica is used as a sensing element for temperature measurement.…”
Section: Introductionmentioning
confidence: 99%
“…This configuration yielded sensitivities of 9.95×104 nm ppb1 for Ni2+, 2.31×104 nm ppb1 for Zn2+, and 4×104 nm ppb1 for Na+. Interferometric sensors are further categorized based on their principle of operation into Mach–Zehnder interferometers (MZI), 66 , 67 Fabry–Perot interferometers (FPI), 68 , 69 Michelson interferometers (MI), 70 , 71 and Sagnac interferometers, 72 , 73 each with specific applications and advantages.…”
Section: Classification and Basic Principles Of Optical Fiber Sensormentioning
confidence: 99%
“…Figure 3 presents typical configurations of a FOMI. Figure 3a presents a FOMI comprised of two segments of fibers with different core diameters [120,121], while in Figure 3b, the pieces of the same fiber are offset [122,123]. Finally, in Figure 3c, a taper segment is sandwiched between two pieces of single-mode fibers (SMFs) [124,125].…”
Section: Michelson-based Sensormentioning
confidence: 99%
“…FOMI sensors are mainly used to measure physical parameters such as temperature (Table 8) and refractive index (Table 7), providing compact solutions. Additionally, a FOMI can be used as a relative humidity sensor [122,127] presenting a sensitivity of −0.166 dB/% RH and −0.083 dB/% RH, while the second structure is relatively more cost effective than the first one. Furthermore, an adiabatic biconical fused fiber taper spliced to an SMF [125] can be used as a displacement and curvature sensor for high-resolution optical instrumentation processes where mechanical bending is an important physical parameter to determine deformations, displacements, and curvature radiuses.…”
Section: Michelson-based Sensormentioning
confidence: 99%