2018
DOI: 10.1016/j.forc.2017.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Large sample neutron activation analysis avoids representative sub-sampling and sample preparation difficulties: An added value for forensic analysis

Abstract: Large sample neutron activation analysis avoids representative sub-sampling and sample preparation difficulties: An added value for forensic analysis. Forensic Chemistry,

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 49 publications
0
5
0
Order By: Relevance
“…IBA results could be theoretically affected by surface contamination of items (a reasonable hypothesis when dealing with illegal products), INAA avoids representative sub-sampling and sample preparation difficulties, providing results from the bulk of the material. IBA is perfectly suitable for discriminating between authentic Viagra® and illegal sildenafil-based products and surface contaminants makes this job easier but when collecting information for chemical profiling, the INAA bulk approach is definitely an added value for forensic analysis, as expected based on already published research [28].…”
Section: Discussionmentioning
confidence: 99%
“…IBA results could be theoretically affected by surface contamination of items (a reasonable hypothesis when dealing with illegal products), INAA avoids representative sub-sampling and sample preparation difficulties, providing results from the bulk of the material. IBA is perfectly suitable for discriminating between authentic Viagra® and illegal sildenafil-based products and surface contaminants makes this job easier but when collecting information for chemical profiling, the INAA bulk approach is definitely an added value for forensic analysis, as expected based on already published research [28].…”
Section: Discussionmentioning
confidence: 99%
“…In 2018, Bode et al. [ 90 ] discovered that Neutron Activation Analysis (NAA) can analyze large samples without need of pre-treatments. This allows less error or contamination to occur.…”
Section: Glass Measurementsmentioning
confidence: 99%
“…Comparing with the methods above, highsensitive thermal neutron INAA (σ 0 = 98. 7 barn, 197 Au(n, γ) 198 Au), taking account of its advantages [5,13,14], seems being the most suitable method to analyze solid volumetric samples for Au content provided neutron self-shielding and gamma-ray self-absorption by the samples are considered, and the corrections for sample size deviation from the "point source" during irradiation and counting are made [15]. Different approaches both semi-empirical and theoretical are developed to evaluate and account these corrections mainly for the regularshaped (cylindrical) samples [16,17].…”
Section: Introductionmentioning
confidence: 99%