2019
DOI: 10.1002/tal.1679
|View full text |Cite
|
Sign up to set email alerts
|

Large‐scale shaking table test on pile‐soil‐structure interaction on soft soils

Abstract: SUMMARY The two large‐scale shaking table tests of tall buildings on soft soils in pile group foundations are performed to capture the effect of the seismic pile‐soil‐structure interaction (PSSI) on the dynamic responses of the pile, soil, and structure. The two different model conditions are observed, including a fixed‐base structure and a structure supported by 3‐by‐3 pile group foundation in soft soil, representing the situations excluding the soil‐structure interaction (SSI) and considering the SSI, respec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(15 citation statements)
references
References 41 publications
1
14
0
Order By: Relevance
“…The results of the pile bending moment demonstrate that the pile at the middle of first row P2 had a significantly higher bending moment than the other instrumented piles, because the pile P2 shared more load and it was influenced by the shadowing effect. The shadow effect was also found in other researches [47][48].…”
Section: Bending Moment Results and Discussionsupporting
confidence: 70%
“…The results of the pile bending moment demonstrate that the pile at the middle of first row P2 had a significantly higher bending moment than the other instrumented piles, because the pile P2 shared more load and it was influenced by the shadowing effect. The shadow effect was also found in other researches [47][48].…”
Section: Bending Moment Results and Discussionsupporting
confidence: 70%
“…The section of single pile is 75 × 75 mm, and the length is 2 m. All of the physical quantities are scaled using similitude formulas derived from the Buckingham π theorem. [34] In the SSI shaking table tests, a laminar shear box is designed to reduce the undesirable boundary effects, as presented in Figure 1. The net size of the shear box is 4,500 × 3,500 × 3,000 mm (length × width × height).…”
Section: Test Designmentioning
confidence: 99%
“…Shear-type steel frame structure is one of the most common engineering structures. In order to make the designed structure safer and more economical, a lot of theoretical research [1,2] and experimental research [3,4] have been carried out. When the stiffness of the beam is much greater than that of the column, this type of structure can be simplified into a lumped mass shear model.…”
Section: Introductionmentioning