2007
DOI: 10.1109/pes.2007.386125
|View full text |Cite
|
Sign up to set email alerts
|

Large-scale Use of FACTS Technology for Damping Inter-Area Oscillations in the Mexican System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…Based on a dynamic model of the MIS for a 2004 test base case, with no PSSs in the system, the characteristics of these oscillation modes have been determined and are given in Figure 2 (Castellanos et al, 2007). Considering the structure of the MIS in Figure 1, inter-area mode 1 is associated with the interaction of machines between the northern and southern regions; inter-area mode 2 involves mainly machines in the W area swinging against machines in the P region, and inter-area mode 3 denotes the interaction of machines in the W area oscillating against machines in the SE region.…”
Section: Inter-area Modes Of Oscillationmentioning
confidence: 99%
See 3 more Smart Citations
“…Based on a dynamic model of the MIS for a 2004 test base case, with no PSSs in the system, the characteristics of these oscillation modes have been determined and are given in Figure 2 (Castellanos et al, 2007). Considering the structure of the MIS in Figure 1, inter-area mode 1 is associated with the interaction of machines between the northern and southern regions; inter-area mode 2 involves mainly machines in the W area swinging against machines in the P region, and inter-area mode 3 denotes the interaction of machines in the W area oscillating against machines in the SE region.…”
Section: Inter-area Modes Of Oscillationmentioning
confidence: 99%
“…In this regard, different alternatives like the installation or retuning of conventional PSSs on main machines of the system, use of automatic load and generation shedding schemes, application of HVDC technology, and exploitation of supplementary controllers on installed FACTS devices have been suggested (Messina et al, 2003;Castellanos et al, 2007). At this point, the study is directed to the analysis and evaluation of the potential benefits of the previously described simple fuzzy PSS, when fitted on key machines of the MIS.…”
Section: System Damping Improvement Trough Sfpsssmentioning
confidence: 99%
See 2 more Smart Citations
“…Over the last few years, several SVCs have been installed in the Mexican system to improve transient stability and dynamic voltage regulation [17]- [ 19]. Primary advantages of SVCs application include steady-state voltage regulation and transient stability enhancement [16].…”
Section: Figs 1 and 2 Show The Eight Control Centers Of Cfe And The mentioning
confidence: 99%