2000
DOI: 10.1080/000164700317411933
|View full text |Cite
|
Sign up to set email alerts
|

Large tumor endoprostheses and extracortical bone-bridging: 28 patients followed 10-20 years

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0

Year Published

2001
2001
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(29 citation statements)
references
References 23 publications
0
29
0
Order By: Relevance
“…6), resection of extra tissue, such as uninvolved joint surfaces, can have major long-term functional consequences [10,13,14,21,27]. Here, we evaluated whether a custom jigassisted bone tumor resection technique reproduces a welldefined preoperative plan more accurately and consistently than traditional manual resection techniques.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…6), resection of extra tissue, such as uninvolved joint surfaces, can have major long-term functional consequences [10,13,14,21,27]. Here, we evaluated whether a custom jigassisted bone tumor resection technique reproduces a welldefined preoperative plan more accurately and consistently than traditional manual resection techniques.…”
Section: Discussionmentioning
confidence: 99%
“…Because the jig is constructed to mate with the bone surface, a proximally based jig must make contact either with the actual surface of the bone surrounding the tumor or with the periosteum and requires the surgeon peel back soft tissue in the region next to, but not on top of, the tumor to expose the underlying bone (or periosteum). Such soft tissue stripping may decrease the success of a biologically based reconstruction [23,27,28].…”
Section: Appendix 1 Proximally Based Versus Distally Based Jig Designmentioning
confidence: 99%
“…The result is stress-shielding of the surrounding bone and a higher risk of aseptic loosening [5,17,20,29,30,39,41,53,59,60]. Interestingly, studies seldomly point to the prosthetic design as the cause of aseptic loosening [ 17, 56,64].…”
Section: Introductionmentioning
confidence: 99%
“…Interestingly, studies seldomly point to the prosthetic design as the cause of aseptic loosening [ 17, 56,64]. The anatomic location, percentage of bone resected, age of the patient, number of screws used for cross-fixation, positioning of the implant, osteoporotic bone, or insufficient mobilization are more often suspected causes, if at all discussed [1, 8,23,27,41,45,53,57,59,691.…”
Section: Introductionmentioning
confidence: 99%
“…A higher complication rate is well known and accepted because of the extended bone and soft tissue defects, the complex biomechanical reconstruction and the size of the implants [5,7,24].…”
Section: Introductionmentioning
confidence: 99%