2018
DOI: 10.1186/s12871-018-0617-2
|View full text |Cite
|
Sign up to set email alerts
|

Laryngeal mask airway Unique™ position in paediatric patients undergoing magnetic resonance imaging (MRI): prospective observational study

Abstract: BackgroundLaryngeal mask UNIQUE® (LMAU) is supraglottic airway device with good clinical performance and low failure rate. Little is known about the ideal position of the LMAU on the magnetic resonance imaging (MRI) and whether radiological malposition can be associated with clinical performance (audible leak) in children. The primary aim of the study was to evaluate incidence of the radiologic malposition of the LMAU according to size. The secondary outcome was the clinical performance and associated complica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…The LMA has also gained more popularity in MRI in pediatrics in the past years through airway complication rate reduction, lower intrusive nature, excellent clinical performance, and low failure rate ( 11 ). Our results presented that the MRI scan performed by LMA was superior to Guedel oral airway in image quality with comparable needed anesthesia (the mean sevoflurane percent and patients who required propofol boluses were comparable between both groups).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The LMA has also gained more popularity in MRI in pediatrics in the past years through airway complication rate reduction, lower intrusive nature, excellent clinical performance, and low failure rate ( 11 ). Our results presented that the MRI scan performed by LMA was superior to Guedel oral airway in image quality with comparable needed anesthesia (the mean sevoflurane percent and patients who required propofol boluses were comparable between both groups).…”
Section: Discussionmentioning
confidence: 99%
“…The LMA was positioned through the conventional technique, partially inflated, and the tip of the mask was lubricated by clear liquid lubricating jelly after the induction of anesthesia with the patient’s head in the neutral position. The LMA proper position was described as placement in the hypopharynx, the proximal cuff of LMA opposing C1 or C2 vertebrae, with a distance between proximal cuff end and aditus laryngis (distance A) as well as between distal cuff end and aditus laryngis (distance B) ( 11 ). If LMA or airway displacement during anesthesia occurred, their position was corrected, and MRI was restarted.…”
Section: Methodsmentioning
confidence: 99%
“…13,15,16 The structural optimal positioning of the SGA has been evaluated using fiberoptic bronchoscopy, 5 US, 6,17 CT, and MRI. 18,19 In previous studies, SGA location was scored according to the degree of visible structure of the SGA inner outlet using fiberoptic bronchoscopy. 5,20 The position of the SGA was considered to be unstable when larynx obstruction was observed, the SGA was rotated on fiberoptic view.…”
Section: Discussionmentioning
confidence: 99%
“…The structural optimal positioning of the SGA has been evaluated using fiberoptic bronchoscopy, 5 US, 6,17 CT, and MRI 18,19 . In previous studies, SGA location was scored according to the degree of visible structure of the SGA inner outlet using fiberoptic bronchoscopy 5,20 .…”
Section: Discussionmentioning
confidence: 99%
“…[ 48 , 49 , 50 , 51 ] with comparable efficacy and lower incidence of associated complications in comparison to tracheal tubes [ 52 , 53 ], the supraglottic airways should always be considered as the device of choice in all situations possible (fasted patient, low risk of aspiration/regurgitation, and possible access to head and airway of the patient). Currently, multiple types of laryngeal masks are available on the market, but the majority are equipped with an inflatable cuff to obtain an adequate perilaryngeal seal (cuff located in the hypopharynx) after inflation [ 54 ]. The proper cuff management is vital also in case of laryngeal mask cases due to the risk of oropharyngeal and hypopharyngeal mucosal cuff-related pressure damage.…”
Section: Airway Management In Pediatric Anesthesiologymentioning
confidence: 99%