1989
DOI: 10.1002/aic.690350703
|View full text |Cite
|
Sign up to set email alerts
|

Laser capillary spectrophotometry for drop‐size concentration measurements

Abstract: A laser capillary spectrophotometric technique (LCS), based on the method of Verhoff et al. (1969Verhoff et al. ( , 1977, is developed for the rapid and accurate determination of the bivariate drop size-concentration distribution for reactive liquid-liquid dispersions. The method employs a precision bore capillary, through which a sample is drawn from the mixing vessel by a vacuum pump. An appropriate light source is used to distinguish between the slugs of dispersed phase and continuous phase as the sample pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
19
0

Year Published

1994
1994
2015
2015

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(20 citation statements)
references
References 35 publications
1
19
0
Order By: Relevance
“…The specific gas-liquid interfacial area is usually determined using a light scattering technique (Calderbank, 1958;Calderbank et al, 1960), or by simultaneous determination of the gas holdup and the bubble-size distribution. Methods to determine the bubble diameter include photography (with digital image analysis) (Machon et al, 1997;Pacek et al, 1994) and capillary techniques with light transmission analysis (Barigou and Greaves, 1991;Bae and Tavlarides, 1989) or by using contact probes (Burgess and Calderbank, 1975;Calderbank and Pereira, 1977). However, all these techniques have limited applicability, because they only allow for small volume fractions and require transparent solutions.…”
Section: Introductionmentioning
confidence: 99%
“…The specific gas-liquid interfacial area is usually determined using a light scattering technique (Calderbank, 1958;Calderbank et al, 1960), or by simultaneous determination of the gas holdup and the bubble-size distribution. Methods to determine the bubble diameter include photography (with digital image analysis) (Machon et al, 1997;Pacek et al, 1994) and capillary techniques with light transmission analysis (Barigou and Greaves, 1991;Bae and Tavlarides, 1989) or by using contact probes (Burgess and Calderbank, 1975;Calderbank and Pereira, 1977). However, all these techniques have limited applicability, because they only allow for small volume fractions and require transparent solutions.…”
Section: Introductionmentioning
confidence: 99%
“…Several techniques have been developed since the second half of the twentieth century to study the bubbles/droplets/particle size distributions in heterogeneous systems (gas–liquid, liquid–liquid and solid–liquid) to understand and control the evolution of these distributions in chemical processes . These techniques are often based on laser spectroscopy, capillary spectroscopy , laser scattering , near‐infrared spectroscopy , and backscattered lighting .…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, g(n) has been assumed to be such that the flux,f(n), is convex. It should be remembered that in a liquid-liquid dispersion, though the number density of drops, n(v,x, t ) , can be measured experimentally [6,7], it is a tedius procedure. However, the volume fraction of the dispersed phase, E , which relates the number density through…”
Section: Introductionmentioning
confidence: 99%