2016
DOI: 10.1016/j.bios.2016.06.061
|View full text |Cite
|
Sign up to set email alerts
|

Lateral flow based immunobiosensors for detection of food contaminants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
64
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 155 publications
(64 citation statements)
references
References 116 publications
0
64
0
Order By: Relevance
“…For analysis of PHC and HPC (in triplicate) the normalization of the (L)LAB values was carried out by dividing the L values of the test lines by the L values of the control lines. The method of dividing the test line response by the control line response (T/C ratio) is a technique commonly used for the quantification of sandwich LFIAs [35,[47][48][49]. The results for PHC can be found in Figure 4, and the HPC smartphone calibration curve can be found in Figure S4 in Supplementary Information.…”
Section: Smartphone Readout and Analysismentioning
confidence: 99%
“…For analysis of PHC and HPC (in triplicate) the normalization of the (L)LAB values was carried out by dividing the L values of the test lines by the L values of the control lines. The method of dividing the test line response by the control line response (T/C ratio) is a technique commonly used for the quantification of sandwich LFIAs [35,[47][48][49]. The results for PHC can be found in Figure 4, and the HPC smartphone calibration curve can be found in Figure S4 in Supplementary Information.…”
Section: Smartphone Readout and Analysismentioning
confidence: 99%
“…For the fabrication of disposable electrochemical and colorimetric sensors for food analysis, cellulose and its derivatives, such as nitrocellulose, are among the materials most commonly used . Cellulose‐based materials have the obvious advantage that they can be ultralow cost, and various biomolecules can be immobilized or freeze‐dried on the hydrophilic surface without much effort.…”
Section: Fields Of Applicationmentioning
confidence: 99%
“…Some assays achieve high specificity by focusing on antibody-antigen interactions that form very rapidly. For example, in lateral flow devices each protein may have to be bound in seconds as it passes an immobilized capture antibody, thereby discriminating against nonspecific interaction with a slower on-rate [26,27]. Conversely, many assays require antibodies to remain bound to their target molecules for an extended time, again minimizing background from low-affinity interactions.…”
Section: What Affinity Reagents To Use?mentioning
confidence: 99%