2022
DOI: 10.1016/j.molliq.2021.117907
|View full text |Cite
|
Sign up to set email alerts
|

Lateral organization of biomimetic cell membranes in varying pH conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
3

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 76 publications
0
5
0
Order By: Relevance
“…The membranes were prepared either in Milli-Q water or in a buffer with the addition of 5 mM up to 1.5 M of NaCl. As the pH of the buffer has a prominent effect on the phase separation in lipid membranes, 25 10 mM HEPES buffer was used to keep the pH of the medium constant at pH = 5.2, equal to that of Milli-Q water (see Experimental section in ESI † ). Representative confocal images of the phase-separated SLBs prepared in Milli-Q water as well as in buffers of different composition are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The membranes were prepared either in Milli-Q water or in a buffer with the addition of 5 mM up to 1.5 M of NaCl. As the pH of the buffer has a prominent effect on the phase separation in lipid membranes, 25 10 mM HEPES buffer was used to keep the pH of the medium constant at pH = 5.2, equal to that of Milli-Q water (see Experimental section in ESI † ). Representative confocal images of the phase-separated SLBs prepared in Milli-Q water as well as in buffers of different composition are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…The membranes were prepared either in Milli Q water or in a buffer with the addition of 5 mM up to 1.5 M of NaCl. As the pH of the buffer has a prominent effect on the phase separation in lipid membranes 25 , 10 mM HEPES buffer was used to keep the pH of the medium constant at pH=5.2, equal to that of Milli Q water (see experimental section). Representative confocal images of the phaseseparated SLBs prepared in Milli Q water as well as in buffers of different composition are shown in Figure 1A.…”
Section: Impact Of Na + Ions On the Structure Of Slbsmentioning
confidence: 99%
“…SLBs were formed using a previously reported method. 39 Briefly, lipid vesicles were diluted 10 times to a final lipid concentration of 1 mM by addition of HEPES buffer. Aliquots containing MLVs were sonicated in a Bransonic 1800 ultrasonic bath for 10 min to generate small unilamellar vesicles (SUVs).…”
Section: Slb Preparationmentioning
confidence: 99%