2010
DOI: 10.1016/j.talanta.2009.04.053
|View full text |Cite
|
Sign up to set email alerts
|

Latest developments in sample treatment for 18O-isotopic labeling for proteomics mass spectrometry-based approaches: A critical review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
78
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(78 citation statements)
references
References 33 publications
0
78
0
Order By: Relevance
“…The differences are most pronounced in the HCl-decalcified/gelatinized samples (relative to nongelatinized, EDTA-decalcified collagens). The difference among the collagen/gelatin preparations within each sample likely results from oxygen addition and equilibration that is a necessary consequence of partial hydrolysis and carboxyl exchange at low pH (see Capelo et al 2010). The measurement of oxygen isotopic values in gelatin could serve as a monitor of peptide bond breakage as part of the preparation.…”
Section: Resultsmentioning
confidence: 99%
“…The differences are most pronounced in the HCl-decalcified/gelatinized samples (relative to nongelatinized, EDTA-decalcified collagens). The difference among the collagen/gelatin preparations within each sample likely results from oxygen addition and equilibration that is a necessary consequence of partial hydrolysis and carboxyl exchange at low pH (see Capelo et al 2010). The measurement of oxygen isotopic values in gelatin could serve as a monitor of peptide bond breakage as part of the preparation.…”
Section: Resultsmentioning
confidence: 99%
“…The advantages of 18 O enzymatic labeling are: the fact that virtually all the produced peptides are labeled and co-elute with the correspondent unlabeled peptide; the only reagent specifically required is H 2 18 O; and the procedure is easy to adapt in any proteomics lab [15,16]. On the other hand, the procedure is labor-intensive and time-consuming; the labeling efficiency is influenced by many factors (such as pH, enzyme to be used, or the characteristics of the proteins and the peptides); and also if the 18 O-water to be used is less than 95% pure, some of the peptides will be labeled with only one 18 O, resulting in a mass spectra with both 2 Da and m/z O.…”
Section: O Enzymatic Labeling Of Peptidesmentioning
confidence: 99%
“…D) Representation of the iTRAQ 8-plex molecule and the spectra obtained in an iTRAQ experiment with the MS/MS spectrum that is used for identification and a zoom of the low m/z region where the reporter ions are used for quantification. 4 Da mass shifts [15]. Finally, the naturally abundant isotopes may also contribute to the peak intensities making the spectra very complex to analyze and adding the necessity for improved software for data processing [16].…”
Section: O Enzymatic Labeling Of Peptidesmentioning
confidence: 99%
“…Several ways of protein quantitation have been suggested and they can be divided into two main categories; the isotope based and the label free methods. Two papers which give good overviews over the different labeling methods have been published recently (Capelo et al 2010;Vaudel et al 2010). In brief; the main modern strategies for isotopic labeling are divided into metabolic labeling at cell growth called SILAC, chemical labeling at protein level, called iCAT, enzymatic labeling at peptide level, after protein digestion like iTRAQ and labeling during protein digestion, such as 18 O labeling (Capelo et al 2010).…”
mentioning
confidence: 99%
“…Two papers which give good overviews over the different labeling methods have been published recently (Capelo et al 2010;Vaudel et al 2010). In brief; the main modern strategies for isotopic labeling are divided into metabolic labeling at cell growth called SILAC, chemical labeling at protein level, called iCAT, enzymatic labeling at peptide level, after protein digestion like iTRAQ and labeling during protein digestion, such as 18 O labeling (Capelo et al 2010). SILAC can only be used for samples which are produced using labeled amino acids, while the other methods can be used for all types of protein samples.…”
mentioning
confidence: 99%