Lead Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 70 publications
0
8
1
Order By: Relevance
“…Nilsson et al 20 recently reported that a commercially available electrocardiograph could detect 38% of the limb lead reversals in 53 875 ECGs. Most rule‐based models detect only RA‐LA electrode reversal 21 , 22 and cannot identify other combinations of interchange 9 , 12 ; in our study the electrocardiograph identified RA‐LA interchange in only 57.1% of cases. These automated algorithms are also programmed to diagnose other ECG abnormalities, and in the presence of limb interchange, they may make incorrect diagnoses like ectopic atrial rhythm, accelerated junctional rhythm, 23 intraventricular conduction disturbance, 24 , 25 chamber enlargement, ventricular preexcitation, 26 and myocardial ischemia/infarction 27 30 in an essentially normal ECG.…”
Section: Discussioncontrasting
confidence: 66%
“…Nilsson et al 20 recently reported that a commercially available electrocardiograph could detect 38% of the limb lead reversals in 53 875 ECGs. Most rule‐based models detect only RA‐LA electrode reversal 21 , 22 and cannot identify other combinations of interchange 9 , 12 ; in our study the electrocardiograph identified RA‐LA interchange in only 57.1% of cases. These automated algorithms are also programmed to diagnose other ECG abnormalities, and in the presence of limb interchange, they may make incorrect diagnoses like ectopic atrial rhythm, accelerated junctional rhythm, 23 intraventricular conduction disturbance, 24 , 25 chamber enlargement, ventricular preexcitation, 26 and myocardial ischemia/infarction 27 30 in an essentially normal ECG.…”
Section: Discussioncontrasting
confidence: 66%
“…A Cartesian coordinate system was used with the positive X-axis pointed towards the left, the positive Y-axis pointed caudally, and the positive Z-axis pointed posteriorly [13].…”
Section: Methods Populationmentioning
confidence: 99%
“…In the absence of traditionally used Frank's orthogonal leads (X, Y, and Z) [4] or a hybrid lead system based on Frank's image space [16] in a resource poor setting, we used leads I, aVF and V2 as a reasonably close approximation to orthogonal leads.…”
Section: Methodsmentioning
confidence: 99%