1997
DOI: 10.1016/s0954-6111(97)90091-3
|View full text |Cite
|
Sign up to set email alerts
|

Left atrial tumour mimicking pulmonary embolism

Abstract: Primary cardiac tumours have been described as great imitators. They are rare, and clinical presentations are diverse. Diagnosis is usually made by two-dimensional echocardiography. The present case report describes a case where a left atrial fibrosarcoma eluded diagnosis by echocardiography, and was eventually demonstrated by computed tomography. Management was complicated by the presence of persistent mismatch demonstrated by ventilation-perfusion lung scans. The likely mechanism underlying this phenomenon i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

1998
1998
2009
2009

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…The diagnostic sensitivities of transthoracic and transesophageal echocardiography are 93.3% and 96%, respectively [31]. However, cases have been described where cardiac sarcomas have eluded diagnosis by echocardiography and were eventually demonstrated by CT or by open tumour biopsy [32,33] TOE guides transvenous tumour biopsies especially with right atrial masses [34], thereby avoiding invasive diagnostic procedures [35].…”
Section: Echomentioning
confidence: 99%
“…The diagnostic sensitivities of transthoracic and transesophageal echocardiography are 93.3% and 96%, respectively [31]. However, cases have been described where cardiac sarcomas have eluded diagnosis by echocardiography and were eventually demonstrated by CT or by open tumour biopsy [32,33] TOE guides transvenous tumour biopsies especially with right atrial masses [34], thereby avoiding invasive diagnostic procedures [35].…”
Section: Echomentioning
confidence: 99%
“…At CT, low-attenuation tumor may obliterate entire chambers (72,73). Some reports have described necrotic areas in gross pathologic specimens (69), and others have described a similar appearance at CT (74).…”
mentioning
confidence: 99%
“…In one example, a large hemorrhagic angiosarcoma infiltrated the right atrium and ventricle, but a series of successive echocardiograms did not suggest an intracardiac tumor 6 . In another report, a left atrial high‐grade fibrosarcoma occupying the entire left atrium and obstructing pulmonary venous inflow was missed on transthoracic echocardiography and was revealed only by a transesophageal study 7 …”
Section: Discussionmentioning
confidence: 99%