“…LBBAP in patients with dextrocardia using the lumenless Medtronic SelectSecure 3830 lead has been recently reported. 10 , 11 Our case is the first to report a successful implant of a standard stylet-driven lead with an extendable helix design, the Biotronik Solia S60, in a patient with dextrocardia. LBBAP using a stylet-driven lead was shown to be comparable to the lumenless lead in terms of procedural and fluoroscopic times, success rates, and lead parameters.…”