2017
DOI: 10.1016/j.jpeds.2016.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Left Ventricular Function in Healthy Term Neonates During the Transitional Period

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
62
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 58 publications
(65 citation statements)
references
References 26 publications
2
62
0
1
Order By: Relevance
“…Echocardiograms were performed using the Phillips iE33 ultrasound machine equipped with a standard transducer (Phillips Healthcare, Andover, MA, USA). The echocardiogram images obtained adhered to the American Society of Echocardiography (ASE) protocols for transthoracic pediatric echocardiograms [12-14]. This included 2D imaging, color Doppler, and spectral Doppler in the subcostal, parasternal short axis, parasternal long axis, apical four chamber (4C), and suprasternal notch views.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Echocardiograms were performed using the Phillips iE33 ultrasound machine equipped with a standard transducer (Phillips Healthcare, Andover, MA, USA). The echocardiogram images obtained adhered to the American Society of Echocardiography (ASE) protocols for transthoracic pediatric echocardiograms [12-14]. This included 2D imaging, color Doppler, and spectral Doppler in the subcostal, parasternal short axis, parasternal long axis, apical four chamber (4C), and suprasternal notch views.…”
Section: Methodsmentioning
confidence: 99%
“…This included 2D imaging, color Doppler, and spectral Doppler in the subcostal, parasternal short axis, parasternal long axis, apical four chamber (4C), and suprasternal notch views. Additionally, we employed protocols approved by ASE for newborns during the transition period [12, 13]. All echocardiograms were performed by 1 of 4 registered diagnostic cardiac sonographers with pediatric echocardiography certification.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The echocardiography images and cine loops were stored as raw data and analysed later using dedicated vendor-customised commercially available software (EchoPAC v112; General Electric Medical Systems, Waukesha, WI, USA). A comprehensive echocardiographic assessment to measure bi-ventricular function was performed; detailed methodology is described elsewhere [11,12,15]. …”
Section: Methodsmentioning
confidence: 99%
“…With the emergence of new echocardiography modalities including the deformation and rotational characteristics of the left ventricle, and right ventricle-specific measurements, a detailed characterisation of myocardial performance in various disease states and physiological milieus is now possible [9,10]. Those measurements are feasible in the neonatal population and demonstrate excellent intra- and inter-rater reproducibility [11,12]. …”
Section: Introductionmentioning
confidence: 99%