“…“Chromatographic analysis was performed at the following temperatures: 120 °C for 1 min and then increased to 180 °C at a rate of 20 °C/min, then to 260 °C at a rate of 2 °C/min, and finally to 300 °C at a rate of 5 °C/min for 4 min” [ 95 ] | Soil | 3 | 0.022–0.024 | | 97.8–111.3 | 7.1–13.1 | GC-MS: Splitless. “the column temperature was at 80 °C for 1 min, increased to 150 °C at a rate of 20 °C/min, then increased to 210 °C at a rate of 5 °C/min, and finally increased to 280 °C at a rate of 10 °C/min; thereafter, the temperature remained constant for 5 min” | [ 148 ] |
Soil | 15 | 500–2000 | 1000–2x10 4 | | | GC-MS: Splitless, “the oven temperature was programmed starting at 45 °C and held 0.5 min, followed by an increase of 30 °C min ─1 up to 90 °C, held 0.5 min, then 10 °C min ─1 up to 310 °C for 3 min” | [ 149 ] |
Soil | 28 | 0.036–0.183 | | | | GC-ECD: “the oven temperature began at 100 °C (equilibrium time 1 min), rose to 200 °C at 4 °C/min, then to 230 °C at 2 °C/min, and at last reached 280 °C at a rate of 8 °C/min, held for 15 min” | [ 150 ] |
Soil | 25 | 0.018–0.058 | 0.062–0.199 | Surrogate: 59.2–124 | | GC-ECD: “The oven temperature was set to start from 100 °C (held for 1 min), and then increased by a rate of 4 °C/min to 200 °C, by a rate of 2 °C/min to 230 °C, and at last by a rate of 8 °C/min to 280 °C, with a final holding time of 15 min” | [ 151 ] |
Soil | 25 | MDL: 0.001–0.02 | | 74.8 and 86.9 | <20 %; | GC-ECD/GC-MS: “initially 100 °C for 1 min, 4 °C/min to 200 °C, 2 °C/min to 230 °C, and 8 °C/min to 280 °C for 15 min” | [ 152 ] |
Soil | 26 | |
…”