2021
DOI: 10.1016/j.heliyon.2021.e06924
|View full text |Cite
|
Sign up to set email alerts
|

Levels of heavy metals in ginger (Zingiber officinale Roscoe) from selected districts of Central Gondar Zone, Ethiopia and associated health risk

Abstract: In this study, we investigated the concentrations of Cd, Cr, Cu, Fe, Ni, Pb and Zn; and their associated health risks through consumption of ginger. After the ginger samples digested with a mixture of HNO 3 and HClO 4 at 200 C for 2:00 h, the amount of metals were investigated by flame atomic absorption spectrometry (FAAS). Efficiency of the analytical measurement was validated on spiking the sample with standard solutions of metals and the recovery for all studied metals were ranged from 91.60% to 99.94%, whi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
17
2

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 16 publications
(21 citation statements)
references
References 26 publications
2
17
2
Order By: Relevance
“…The regression coefficients (R 2 ) of the calibration were greater than 0.99, indicating that there was a very good association between absorbance and the concentration of metals. The detection limits were calculated as the concentrations that provide signals equal to three times the standard deviations of the blanks [ 26 ]. The limit of quantification (LOQ) is the lowest concentration of an analyte in a sample and quantitatively calculated with acceptable uncertainty using 10 times the standard deviation of the blank.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The regression coefficients (R 2 ) of the calibration were greater than 0.99, indicating that there was a very good association between absorbance and the concentration of metals. The detection limits were calculated as the concentrations that provide signals equal to three times the standard deviations of the blanks [ 26 ]. The limit of quantification (LOQ) is the lowest concentration of an analyte in a sample and quantitatively calculated with acceptable uncertainty using 10 times the standard deviation of the blank.…”
Section: Methodsmentioning
confidence: 99%
“…If the value of HI ≀ 1, it is assumed that non-carcinogenic risks have no substantial impact. If HI > 1, however, there is a risk that non-carcinogenic effects will occur, and the likelihood increases as HI increases [ 26 , 36 ].…”
Section: Methodsmentioning
confidence: 99%
“…The degree of toxicity of heavy metals to human upon their daily intake (mg/kg/day) known as the EDI was computed for each element as described by [16].…”
Section: Baf = C Plant /C Soilmentioning
confidence: 99%
“…Adult body weight was taken as an average of 60 kg. To determine the degree of toxicity, the computed EDI values was compared with acceptable level of Oral reference dose (RfD) set by [16].…”
Section: Edi=mentioning
confidence: 99%
See 1 more Smart Citation