2012
DOI: 10.1016/j.jcrs.2012.03.038
|View full text |Cite
|
Sign up to set email alerts
|

Light scattering and light transmittance in intraocular lenses explanted because of optic opacification

Abstract: No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
35
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(44 citation statements)
references
References 30 publications
1
35
0
Order By: Relevance
“…[13][14][15] In previous studies, we evaluated light scattering and light transmission in IOLs explanted because of clinically significant postoperative opacification. 16,17 Very high levels of light scattering and a potential for decrease in light transmittance were found. However, only back scattered light was measured with a Scheimpflug camera (dispersion of light reflected out of the eye that can be seen by an external observer).…”
mentioning
confidence: 99%
“…[13][14][15] In previous studies, we evaluated light scattering and light transmission in IOLs explanted because of clinically significant postoperative opacification. 16,17 Very high levels of light scattering and a potential for decrease in light transmittance were found. However, only back scattered light was measured with a Scheimpflug camera (dispersion of light reflected out of the eye that can be seen by an external observer).…”
mentioning
confidence: 99%
“…The results show that the absorbance peak in the ultraviolet range for pure PSF was at 268 nm, which represents the UV damage peak for the polymers [19][20][21], whilst the transmittance peak in the visible range for pure PSF was 712.5 nm. The transmittance peak indicates the real effectiveness for pure PSF [21]. The absorbance and transmittance peak values were adopted for all subsequent measurements on the blended samples under study, as well as the sample transparency.…”
Section: Characterizationmentioning
confidence: 96%
“…The absorbance of high photon energy within the UV region led to scission in the polymer chain. More precisely, chromophoric groups, which are capable of absorbing the UV energy involved in the photochemical degradation reactions that occur via free radical mechanisms, led to the formation of hydroperoxides and chain scission of the polymer (Charlesby and Thomas 1962;Abouelezz and Waters 1978;Michelson et al 2012). The transmittance peak for pure PMMA in the visible region was 798 nm.…”
Section: Characterisationmentioning