2010
DOI: 10.1063/1.3452334
|View full text |Cite
|
Sign up to set email alerts
|

Light scattering from human corneal grafts: Bulk and surface contribution

Abstract: The cornea is the only transparent tissue in the body. The transparency is the main characteristic of the corneal tissue, and depends not only on the transmission coefficient but also on the losses by scattering and absorption. The scattering properties of the cornea tissues become one of the most important parameters in the case of the corneal graft. These scattering properties are studied in this paper in the reflected half area, similar to the diagnosis configuration. We quantify the influence of the cornea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…This is of interest in many cases, for example to eliminate or optimize light scattering from optical coatings used in, e.g., imaging systems and within the paper industry [1,2]. Restoration and conservation of art, where the bulk scattered light can be used to identify pigments [3], and studies of the transparency of the cornea for early detection of edema [4] are other examples.…”
Section: Introductionmentioning
confidence: 99%
“…This is of interest in many cases, for example to eliminate or optimize light scattering from optical coatings used in, e.g., imaging systems and within the paper industry [1,2]. Restoration and conservation of art, where the bulk scattered light can be used to identify pigments [3], and studies of the transparency of the cornea for early detection of edema [4] are other examples.…”
Section: Introductionmentioning
confidence: 99%
“…While the curves aspect is rather similar for large angles, we notice disparities for low angles (typically inferior to 20°). As already mentioned in [ 17 ], while a major bulk scattering influence is expected for high angles, surface roughness and bulk effect may be more difficult to discriminate for lower angles. As we studied here different samples, their surfaces were likely to vary from one graft to another following the manipulations they were submitted to.…”
Section: Experimental Investigationsmentioning
confidence: 83%
“…Scattered light intensity was measured for each corneal graft (preliminary measurements were presented in [ 17 ]). This was preceded and followed by a thickness evaluation using the OCT setup, in order to take into account the dynamic of the cornea whose thickness may evolve over the duration of the entire characterization process (approximately an hour and a half for scattering measurement and OCT imaging).…”
Section: Experimental Investigationsmentioning
confidence: 99%
“…Far-field light scattering measurement has been extensively investigated over recent decades as a non-destructive and very sensitive technique to characterize surfaces and bulks. Interpreting measurements via electromagnetic theories yields the optical properties of materials: roughness spectrum, heterogeneity index, etc[32]. However, because the level of light scattering may be low compared with the specular beam, the measurements require an efficient setup with a high dynamic range.In the setup used in this study, a circle 5 mm in diameter on the sample was illuminated via a Helium Neon (HeNe) laser (632.8nm).…”
mentioning
confidence: 99%