Lightning overvoltage performance of 110kV air-insulated substation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 1 publication
0
6
0
2
Order By: Relevance
“…Further, to assess the ability of LPI to reproduce the observed lightning activity, lightning data from the Lightning Detection Network (LINET) (Betz et al, 2009) (Franc et al, 2016), showing significant improvement in the sensitivity detection toward smaller stroke current amplitudes. For most of the European region (Franc et al, 2016;Jelić et al, 2021), the average minimum detectable signal is 0.7 kA, and the median location accuracy error is ±84 m. Here, we considered total lightning information, i.e., we did not differentiate between types or polarities of lightning flashes as LPI presents the overall potential for lightning activity without preferences to the type or polarity of lightning discharges. The total lightning for the examined cases was taken from the 2D database of lightning flashes at a 3 km x 3 km horizontal and 2 min temporal resolution (developed by Jelić et al, 2021) over the domain shown in Figure 1a.…”
Section: Datementioning
confidence: 99%
See 1 more Smart Citation
“…Further, to assess the ability of LPI to reproduce the observed lightning activity, lightning data from the Lightning Detection Network (LINET) (Betz et al, 2009) (Franc et al, 2016), showing significant improvement in the sensitivity detection toward smaller stroke current amplitudes. For most of the European region (Franc et al, 2016;Jelić et al, 2021), the average minimum detectable signal is 0.7 kA, and the median location accuracy error is ±84 m. Here, we considered total lightning information, i.e., we did not differentiate between types or polarities of lightning flashes as LPI presents the overall potential for lightning activity without preferences to the type or polarity of lightning discharges. The total lightning for the examined cases was taken from the 2D database of lightning flashes at a 3 km x 3 km horizontal and 2 min temporal resolution (developed by Jelić et al, 2021) over the domain shown in Figure 1a.…”
Section: Datementioning
confidence: 99%
“…Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 379(2195). https://doi.org/10.1098/rsta.2019.0542Franc, B., Filipović-Grčić, B., & Milardić, V. (2016). Lightning overvoltage performance of 110 kV air-insulated substation.…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…These are parameters that determine the range of the arising surges and have a great impact on the lightning performance of the substations. In [6] the lightning performance of an air-insulated substation that connects a hydro power plant with network is presented, considering different overvoltage protection schemes. The influence of various parameters (i.e., surge front times, soil resistivity, distance of the cable that connects the transformer and the busbar) on the lightning performance of a combined overhead line/cable connected gas-insulated substation is examined in [7], since the role of the earth grid is revealed in [8].…”
Section: Introductionmentioning
confidence: 99%
“…Trong quá trình vận hành, trạm biến áp thường xuyên chịu tác động của phóng điện sét gây ra quá điện áp đánh thủng cách điện, sự cố ngắn mạch, chạm đất v.v… [1]- [4] hậu quả là làm hư hỏng thiết bị điện và thiết bị điều khiển trong trạm biến áp, gián đoạn cung cấp điện trong thời gian dài, gây mất ổn định hệ thống, mất an toàn cho con người, gây thiệt hại về kinh tế [5]- [9]. Do vậy, việc bảo vệ quá điện áp khí quyển cho trạm biến áp nhằm hạn chế tối đa quá điện áp nguy hiểm xuất hiện trong trạm biến áp [10]- [12], sao cho tần suất phóng điện trung bình trong trạm biến áp do quá điện áp khí quyển đạt tới 50 năm hay 100 năm [11], [13], [14].…”