1984
DOI: 10.1016/0022-0728(84)80115-1
|View full text |Cite
|
Sign up to set email alerts
|

Linear sweep voltammetry at very small stationary disk electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
114
0
1

Year Published

1990
1990
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 299 publications
(124 citation statements)
references
References 29 publications
9
114
0
1
Order By: Relevance
“…Thus, for the disk electrode, the simulated chronoamperometric current deviates from the analytical approximations for short and long times made by Aoki and Osteryoung [51] by no more than 0.24 %, which is within the claimed 0.5 % accuracy of these analytical approximations (see Table 4). At the same time, the simulated steady-state current achieves its analytical value i expression provided by Aoki et al for voltammetry [53] reveals an excellent agreement (see Table 5 showing the results for a wide range of values of the dimensionless voltammetric parameter p ¼ ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi nFr [52] …”
Section: Uncomplicated Electron Transfersupporting
confidence: 51%
“…Thus, for the disk electrode, the simulated chronoamperometric current deviates from the analytical approximations for short and long times made by Aoki and Osteryoung [51] by no more than 0.24 %, which is within the claimed 0.5 % accuracy of these analytical approximations (see Table 4). At the same time, the simulated steady-state current achieves its analytical value i expression provided by Aoki et al for voltammetry [53] reveals an excellent agreement (see Table 5 showing the results for a wide range of values of the dimensionless voltammetric parameter p ¼ ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi nFr [52] …”
Section: Uncomplicated Electron Transfersupporting
confidence: 51%
“…The peak (I) does not change significantly in its shape or height at low scan rates, within 5-20 mV/s, where the large contribution from nonlinear diffusion gives rise to a time-independent flux [6].…”
Section: Resultsmentioning
confidence: 99%
“…[102][103][104][105][106][107][108][109][110][111][112] Dessa forma, a análise matemática dos resultados obtidos nestes casos é dificultada. 104,[107][108][109][110][111][112] Microeletrodos com geometria hemisférica não apresentam esse problema, uma vez que a densidade de corrente no estado estacionário é uniforme em toda a superfície do eletrodo. Além disso, microeletrodos não planares sofrem menos problemas de bloqueio do isolante resultantes de imprecisões no processo de isolamento da microfibra.…”
Section: Microeletrodos Hemisféricosunclassified