Linear Voltage Based State Estimator for Active Distribution System Including Phasor Measurement Unit (PMU)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…From this viewpoint, two types of SE process formulation generally exist in the literature: bus voltage-based and branch current-based formulations. Both of these estimators can be developed in both rectangular and polar coordinates, each one with some unique properties [23]. Based on the features of the voltage-based SE formulation in the rectangular form, i.e., matching with meshed topology, linear measurement function, and low computational burden as presented in [24], this type of estimator is employed for the extraction of system conditions.…”
Section: Active Distribution Network State Estimationmentioning
confidence: 99%
“…From this viewpoint, two types of SE process formulation generally exist in the literature: bus voltage-based and branch current-based formulations. Both of these estimators can be developed in both rectangular and polar coordinates, each one with some unique properties [23]. Based on the features of the voltage-based SE formulation in the rectangular form, i.e., matching with meshed topology, linear measurement function, and low computational burden as presented in [24], this type of estimator is employed for the extraction of system conditions.…”
Section: Active Distribution Network State Estimationmentioning
confidence: 99%
“…In this paper, due to high computational speed, linear measurement functions, constant Jacobian matrix and being suitable for both radial and meshed topologies, voltages of the network buses in rectangular form have been selected as state variables [1]:…”
Section: Dse Formulationmentioning
confidence: 99%
“…Also, as presented in [1], for having linear measurement functions in the rectangular form of voltage-based DSE process, pseudomeasurement and flow measurements are converted into bus injection current measurements and flow current measurements respectively using the available voltage profile of the network. For this purpose, in each iteration, the estimated voltage magnitudes and phase angles in the previous iteration are used.…”
Section: Dse Formulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Distribution networks where PMU based DSSE has been tested are usually benchmark distribution test systems (IEEE, UK test systems, etc.) [29][30][31]. Although examples of small smartgrid distribution networks built up at University Campuses are tested before [32], there is no work reported on real-life distribution network totally covered with PMU measurements.…”
Section: Introductionmentioning
confidence: 99%