2013
DOI: 10.1134/s0020441213010314
|View full text |Cite
|
Sign up to set email alerts
|

Linearity of the energy scale of a detector based on a LaBr3(Ce) scintillator

Abstract: The linearity of a LaBr 3 (Ce) detector response in the energy range of 0.6-11.0 MeV has been investigated using various PMT voltage divider circuits. A tapered voltage divider circuit is proposed to reduce the nonlinearity.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…A high-purity germanium (HPGe) Clover detector of Canberra was placed directly facing to the LaBr 3 (Ce). The high voltage applied for the LaBr 3 (Ce) detector was set to be 520 V. Higher voltage may cause the electron saturation in the photomultiplier, thus can affect linearity [23] in the energy determination. The Clover consists of four coaxial N-type high-purity Germanium detectors, each with a diameter of 60 mm and length of 60 mm.…”
Section: Methodsmentioning
confidence: 99%
“…A high-purity germanium (HPGe) Clover detector of Canberra was placed directly facing to the LaBr 3 (Ce). The high voltage applied for the LaBr 3 (Ce) detector was set to be 520 V. Higher voltage may cause the electron saturation in the photomultiplier, thus can affect linearity [23] in the energy determination. The Clover consists of four coaxial N-type high-purity Germanium detectors, each with a diameter of 60 mm and length of 60 mm.…”
Section: Methodsmentioning
confidence: 99%
“…Gamma-lines are produced by radio isotopes ( 137 Cs, 60 Co, Pu-Be) and neutron interactions on hydrogen (2.2 MeV line), iron (7.6 MeV line) and nitrogen (10.8 MeV line) were used for the LES prototype calibration (Trofimov et al, 2013). The HES prototype was calibrated by LED pulser which is similar to one described in Vicic et al (2003).…”
Section: Investigation Tests Of the Gris Detector Prototypesmentioning
confidence: 99%
“…Therefore, the signal peak-to-charge ratio V p /Q total determined uniquely in all waveforms was noted in this work. Generally, Q total is proportional to V p and for gamma ray events at adequate gamma ray energy region, 23,24 while the V p /Q total value is expected to be a constant. However, we observed different values between alpha and gamma induced events.…”
Section: Introductionmentioning
confidence: 99%