2023
DOI: 10.1007/s00216-023-04602-0
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography and differential mobility spectrometry—data-independent mass spectrometry for comprehensive multidimensional separations in metabolomics

Abstract: The benefits of combining drift time ion mobility (DTIMS) with liquid chromatography–high-resolution mass spectrometry (HRMS) have been reported for metabolomics but the use of differential time mobility spectrometry (DMS) is less obvious due to the need for rapid scanning of the DMS cell. Drift DTIMS provides additional precursor ion selectivity and collisional cross-section information but the separation resolution between analytes remains cell- and component-dependent. With DMS, the addition of 2-propanol m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…In this subsection, we analyze our recent results 24 for a 50 analytes mixture (Figure S1 and Table 1), representative for urine and plasma metabolites, Figure 1. The data include respective LC retention time (RT) and CoV values for pure N 2 , 1.5% mole ratio of cyclohexane (Ch), ethanol (EtOH), isopropanol (IPA), toluene (Tol), acetonitrile (ACN), and one binary modifier: 0.05% mole ratio IPA in Ch.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In this subsection, we analyze our recent results 24 for a 50 analytes mixture (Figure S1 and Table 1), representative for urine and plasma metabolites, Figure 1. The data include respective LC retention time (RT) and CoV values for pure N 2 , 1.5% mole ratio of cyclohexane (Ch), ethanol (EtOH), isopropanol (IPA), toluene (Tol), acetonitrile (ACN), and one binary modifier: 0.05% mole ratio IPA in Ch.…”
Section: Resultsmentioning
confidence: 99%
“…A mix of 50 analytes, representative for urine and plasma metabolites (Figure S1 and Table S1), was analyzed by LC‐MS on a quadrupole time‐of‐flight (QTOF) mass spectrometer (TTOF 6600+, Sciex, Concord, ON, Canada) and was equipped with a differential ion mobility device (SelexION, Sciex). All details about chemicals, sample preparation, LC, DMS and MS experiments can be found in published work 24 …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations