1997
DOI: 10.1016/s0021-9673(96)01004-7
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography—mass spectrometry with on-line solid-phase extraction by a restricted-access C18 precolumn for direct plasma and urine injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
27
0

Year Published

1998
1998
2005
2005

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 68 publications
(29 citation statements)
references
References 28 publications
2
27
0
Order By: Relevance
“…The ADS column can tolerate up to 80-100 ml of plasma [50,53,54]. The LiChrospher ADS-RP was able to achieve the direct analysis of pharmaceutical compounds in several biological matrices such as plasma [49,50,53,[55][56][57][58][59][60][61][62][63][64][65][66][67][68][69][70][71][72][73], serum [42,43,[74][75][76][77][78][79], urine [60,75,76,78,80], microdialysate [81,82], saliva [64], liver homogenate [49], intestinal aspirates [76], cell cultures [68,83], bronchial secretions [74], milk [84] and tissue [67].…”
Section: Alkyl-diol-silica Materialmentioning
confidence: 99%
“…The ADS column can tolerate up to 80-100 ml of plasma [50,53,54]. The LiChrospher ADS-RP was able to achieve the direct analysis of pharmaceutical compounds in several biological matrices such as plasma [49,50,53,[55][56][57][58][59][60][61][62][63][64][65][66][67][68][69][70][71][72][73], serum [42,43,[74][75][76][77][78][79], urine [60,75,76,78,80], microdialysate [81,82], saliva [64], liver homogenate [49], intestinal aspirates [76], cell cultures [68,83], bronchial secretions [74], milk [84] and tissue [67].…”
Section: Alkyl-diol-silica Materialmentioning
confidence: 99%
“…The values are worse for proteins; with numbers ranging from 0.1 to 1 mg/mL, corresponding to 10 -9 -10 -8 mol/L concentrations [140]. Note that enrichment factors of approximately 1000 are possible if a sample preconcentration (e.g., SPE) step after PIEF is employed [140][141][142]. An LOD in the low femtomole range can be obtained with nanoflow LC-MS instruments [23], while a low picomole range has been obtained for peptides (0.5-7 kDa) using a special SEC microcolumn (30 cm6300 mm ID, 2 mL/min flow rate hyphenated to a mass spectrometer.…”
Section: Detectionmentioning
confidence: 99%
“…However, such approaches did not work adequately for the recovery of the penicillins from the matrix containing Micafungin (poor recovery rate up to 40%, data not shown), and careful attention was required to handle a trace amount of the penicillins during the extraction procedure. To improve the accuracy of the method without extraordinary handling, an on-line extraction was examined using the column switching technique, [11][12][13][14] which enables reduction of the loss of analytes during the extraction procedure. Figure 3 shows diagrams of an HPLC equipped with a valve for the column switching technique.…”
Section: Resultsmentioning
confidence: 99%