2020
DOI: 10.37358/rc.20.1.7818
|View full text |Cite
|
Sign up to set email alerts
|

Liquid Chromatography Tandem Mass Spectrometry Method for Ultra-Trace Analysis of Organic UV Filters in Environmental Water Samples

Abstract: A liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) method was developed and validated for the simultaneous determination of six organic compounds (2-hydroxy benzophenone, 4hydroxy benzophenone, 2,2',4,4'-tetrahydroxy benzophenone, 2,4-dyhydroxy benzophenone, 4,4'dyhydroxy benzophenone, 2,2'-dyhydroxy-4-methoxy-benzophenone) used as UV filters in personal care products used to protect against UV radiation. The major concern about this type of pollutants is due to their persistence and bioaccumulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…However, the linear range was rather short (2–10 mg/L) compared with other methods [ 65 ]. In another work, Chiriac et al compared two types of SPE cartridges, in order to determine the optimum for the detection of six BPs and to develop an analytical method [ 66 ]. The authors used Strata C18 cartridges, achieving recoveries between 81.9 and 96.4%, and Strata-X cartridges (pore size of 30μm, polymeric reverse phase), attaining somewhat lower recoveries (74.0–82.6%) [ 66 ].…”
Section: Sample Preparation For Benzophenone Detectionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the linear range was rather short (2–10 mg/L) compared with other methods [ 65 ]. In another work, Chiriac et al compared two types of SPE cartridges, in order to determine the optimum for the detection of six BPs and to develop an analytical method [ 66 ]. The authors used Strata C18 cartridges, achieving recoveries between 81.9 and 96.4%, and Strata-X cartridges (pore size of 30μm, polymeric reverse phase), attaining somewhat lower recoveries (74.0–82.6%) [ 66 ].…”
Section: Sample Preparation For Benzophenone Detectionmentioning
confidence: 99%
“…In another work, Chiriac et al compared two types of SPE cartridges, in order to determine the optimum for the detection of six BPs and to develop an analytical method [ 66 ]. The authors used Strata C18 cartridges, achieving recoveries between 81.9 and 96.4%, and Strata-X cartridges (pore size of 30μm, polymeric reverse phase), attaining somewhat lower recoveries (74.0–82.6%) [ 66 ]. The developed method achieved enrichment factors (EF) of 200 and 100 for surface water and wastewater, respectively.…”
Section: Sample Preparation For Benzophenone Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…One is gas chromatography with tandem mass spectrometry (GC-MS/MS) (da Silva et al, 2015;Huang et al, 2016;Ramos et al, 2019), which has a huge potential for identification and selectivity in separation. Another technique is liquid chromatography with tandem mass spectrometry (LC-MS/ MS) (Li et al, 2020b;Chiriac et al, 2020;Cadena-Aizaga et al, 2022), which is characterized by exceptional sensitivity and is very suitable for the analysis of lowvolatile and degradable UVFs.…”
Section: Introductionmentioning
confidence: 99%
“…A current problem for aquatic ecosystems that can cause a change in the natural balance of flora and fauna is the discharge of industrial and domestic wastewater loaded with various xenobiotic dyes into natural receptors usually represented by rivers and lakes [5]. Among the industrial waters involved are those that come from activities that use dyes in their production cycles.…”
Section: Introductionmentioning
confidence: 99%