2011
DOI: 10.1016/j.aca.2011.02.021
|View full text |Cite
|
Sign up to set email alerts
|

Liquid chromatography tandem mass spectrometry with ion trap and triple quadrupole analyzers for determination of thyreostatic drugs in urine and muscle tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 21 publications
(19 citation statements)
references
References 14 publications
1
18
0
Order By: Relevance
“…The previously published method for urine and muscle samples was used as a starting point for the development of this procedure (29). The positive ionisation was used in the method, as only this ionisation mode is suitable for all investigated compounds.…”
Section: Discussionmentioning
confidence: 99%
“…The previously published method for urine and muscle samples was used as a starting point for the development of this procedure (29). The positive ionisation was used in the method, as only this ionisation mode is suitable for all investigated compounds.…”
Section: Discussionmentioning
confidence: 99%
“…Some researchers have derivatised the ATDs with 3-iodobenzylbromide in order to stabilise them under single tautomeric form, to give them a non-polar behaviour and to increase their masses [10,38,40]. Other researchers have preferred the direct LC-MS detection in positive ion mode to avoid false identification [37] and to make the analysis of these substances simpler and faster when a high number of food or biological samples has to be controlled [34][35][36].…”
Section: Optimisation Of the Lc Conditions And Ms Detectionmentioning
confidence: 97%
“…On the other hand, GC has been used by coupling it to MS [25][26][27][28][29] and nitrogen-phosphorus detection [30]. Most LC methods have relied on UV-vis [31,32] and MS detection [33][34][35][36][37]10,[38][39][40]; some of the latters have included a preliminary derivatization step of the analytes in order to produce compounds with higher molecular weight and lower polarity, which are better retained on reversed phase (RP) columns and which generate a lower MS background resulting in higher S/N ratios [10,[38][39][40].…”
Section: Introductionmentioning
confidence: 99%
“…The analytical protocol describing the preparation of urine samples and LC-MS/MS analysis has been previously published (17). In brief, TU was extracted from urine samples with diethyl ether after derivatization with 3-iodobenzylbromide in basic medium, and detected and identified by means of LC-ESI (+)-MS/MS.…”
Section: Methodsmentioning
confidence: 99%
“…As a result, in some European countries, including Poland, one of thyreostatics -thiouracil (TU) is detected in urine samples of slaughtered animals (7). The examination of urine samples was performed by means of a liquid chromatography coupled with a triple quadrupole mass spectrometry -LC-MS/MS (17).…”
mentioning
confidence: 99%