1994
DOI: 10.1021/je00013a036
|View full text |Cite
|
Sign up to set email alerts
|

Liquid-liquid equilibrium of aqueous mixtures of poly(propylene glycol) with sodium chloride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
110
0
1

Year Published

2006
2006
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 117 publications
(120 citation statements)
references
References 3 publications
9
110
0
1
Order By: Relevance
“…The salt content was subsequently determined by mass balance, considering the proportion in which tri-sodium citrate and citric acid were added to the system. Following Cheluget et al [11], the concentration of polymer in each phase was also determined by refractive index measurements performed at 298.15 K using a refractometer (Model: DR-A1, ATAGO Co., LTD., Japan) with a precision of ± 0.0001. The uncertainties in refractive index measurements are within ±0.0001.…”
Section: Determination Of Tie-linesmentioning
confidence: 99%
See 1 more Smart Citation
“…The salt content was subsequently determined by mass balance, considering the proportion in which tri-sodium citrate and citric acid were added to the system. Following Cheluget et al [11], the concentration of polymer in each phase was also determined by refractive index measurements performed at 298.15 K using a refractometer (Model: DR-A1, ATAGO Co., LTD., Japan) with a precision of ± 0.0001. The uncertainties in refractive index measurements are within ±0.0001.…”
Section: Determination Of Tie-linesmentioning
confidence: 99%
“…Other poly (alkylene glycol)s such as PPGs as close relatives of PEGs, sharing several of their benign properties may also been taking into account as phase polymer in ABS for green separations. However, liquid-liquid equilibrium (LLE) data of the aqueous PPG-polymer and PPG-salt systems are relatively scarce [11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…The experimental apparatus employed is essentially similar to the one used previously [6,10,23]. A glass vessel, volume 50 cm 3 , was used to carry out the phase equilibrium determinations.…”
Section: Apparatus and Proceduresmentioning
confidence: 99%
“…9). Further, the experimental binodal data were fitted by modifying the constants and coefficients of the expressions available in the literature equations (Cheluget et al 1994;Zafarani-Moattar and Hamidi 2003;Regupathi et al 2011).…”
Section: Binodal Curvementioning
confidence: 99%