2015
DOI: 10.1002/jmri.25089
|View full text |Cite
|
Sign up to set email alerts
|

Liver apparent diffusion coefficient repeatability with individually predetermined optimal cardiac timing and artifact elimination by signal filtering

Abstract: Compared to noncardiac-triggered acquisitions, individually optimized cardiac-triggered acquisitions improved ADC repeatability in both liver lobes and reduced ADC differences between left and right liver. Left liver ADC repeatability was further improved after signal filtering.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 27 publications
(27 citation statements)
references
References 21 publications
1
26
0
Order By: Relevance
“…Some solutions to reduce the effects of cardiac motion have been proposed. These include the postprocessing method[24] or filtering[27] which corrects the image after signal acquisition or cardiac triggering synchronized with the heart cycle[27,28]. ADC reproducibility was reportedly improved using these methods.…”
Section: Fundamentals and Techniquesmentioning
confidence: 99%
“…Some solutions to reduce the effects of cardiac motion have been proposed. These include the postprocessing method[24] or filtering[27] which corrects the image after signal acquisition or cardiac triggering synchronized with the heart cycle[27,28]. ADC reproducibility was reportedly improved using these methods.…”
Section: Fundamentals and Techniquesmentioning
confidence: 99%
“…The minimum displacement trigger delay found with this approach matched the delay for which the DWI images were less affected by the cardiac‐related signal loss. This method is actually less subjective than a visual assessment of the left liver lobe displacement as suggested before, that moreover could not be used for the right liver or the pancreas. In contrast, the new method is applicable to any region of the liver and probably to other organs as well.…”
Section: Discussionmentioning
confidence: 99%
“…This delay was compared with a trigger time computed from the motion velocity field that corresponded to the minimum displacement. Our hypothesis was to consider the latter to be the best candidate for optimal diffusion‐weighted cardiac triggering . From the motion velocity field, the time interval with minimum movement was also computed.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…20,21 Cardiac triggering is not often used but may have value in DW-MRI in the upper abdomen. 22 Peristaltic motion can be reduced by administration of an anti-peristaltic agent before imaging.…”
Section: Technical Challenges In Data Acquisitionmentioning
confidence: 99%