2022
DOI: 10.1016/j.ndteint.2021.102595
|View full text |Cite
|
Sign up to set email alerts
|

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(13 citation statements)
references
References 63 publications
0
13
0
Order By: Relevance
“…Reconstructions were done using the standard filter back‐projection algorithm of LTT (Livermore Tomography Tools, 1.6.38). [ 10 ] Reconstructed images were converted from 32‐bits to 8‐bits by scaling intensity (add 2 then multiply by 40) and analyzed both in 2D and 3D using Fiji (ImageJ 1.53t). [ 11 ]…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Reconstructions were done using the standard filter back‐projection algorithm of LTT (Livermore Tomography Tools, 1.6.38). [ 10 ] Reconstructed images were converted from 32‐bits to 8‐bits by scaling intensity (add 2 then multiply by 40) and analyzed both in 2D and 3D using Fiji (ImageJ 1.53t). [ 11 ]…”
Section: Methodsmentioning
confidence: 99%
“…Reconstructions were done using the standard filter back-projection algorithm of LTT (Livermore Tomography Tools, 1.6.38). [10] Reconstructed images were converted from 32-bits to 8-bits by scaling intensity (add 2 then multiply by 40) and analyzed both in 2D and 3D using Fiji (ImageJ 1.53t). [11] Trasatti Capacity Contribution Analysis: The gravimetric capacities (Q G,CV ) at different scan rates were first calculated from the corresponding cyclic voltammetry (CV) curves in Figure S13 (Supporting Information) using Equation (3).…”
Section: Methodsmentioning
confidence: 99%
“…For each projection, 12 frames were averaged with exposure times of 1.3 seconds to generate the digital radiograph at that orientation. The 3D volume was reconstructed using Livermore Tomography Tools (LTT) [33] with an effective voxel size of 157 microns. The three aw locations were then inspected at various angles and cross-sections to gauge their visibility.…”
Section: Immersion Ultrasound Analysismentioning
confidence: 99%
“…Images were reconstructed with regularized weighted least squares (RWLS) reconstruction, using total variation regularization. The reconstruction was performed using the Livermore Tomography Tools (LTT) software [21]. We customized weights for RWLS for each scan according to the quality of data in each projection, as will be discussed in Section 3.…”
Section: Data Processing and Image Reconstructionmentioning
confidence: 99%