Abstract: <p>In this paper, a harmonic-treated thyristor-controlled reactor TCR is presented as a linearized harmonic-free compensating susceptance controllable in inductive and capacitive modes. The harmonic-treated TCR is a traditional TCR conditioned in such a manner that it can respond continuously and linearly to capacitive and inductive reactive current demands without noticeable harmonic association or active power contribution. The conditioned configuration is produced by equipping the TCR with self-harmon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…Two static compensators are required to accomplish current balancing of 4-wire loads [9], [15], [26]. The first compensator is built using three similar susceptances connected in delta-form, whereas the second one is built of three identical susceptances connected in star-form.…”
Section: Load Balancing Of 4-wire Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…Two static compensators are required to accomplish current balancing of 4-wire loads [9], [15], [26]. The first compensator is built using three similar susceptances connected in delta-form, whereas the second one is built of three identical susceptances connected in star-form.…”
Section: Load Balancing Of 4-wire Systemsmentioning
confidence: 99%
“…Static Var compensators (SVCs) and static synchronous compensators (STATCOMs) are usually exploited in the treatment of many issues concerning power quality like harmonic's association, voltage unbalance and unbalanced loads [1]- [26]. Unbalanced loads and poor power factor usually lead to significant losses in both generation station and transmission system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This article depicts high power voltage source inverters and very commonly used multistage inverter techniques, including neutral point inverters. This article proposes the working condition of each method and evaluates the most suitable modulation methods, mainly focusing on the modulation methods proposed in this field [9], [10]. The cascaded multistage inverter synthesizes the average voltage result based on the series association of the power cells using a very less voltage element configuration [11].…”
Section: Introductionmentioning
confidence: 99%
“…Diferent voltage balancing techniques have been proposed to ensure that the voltages in the three phases of the system are equal, leading to better performance, improved energy efciency, and reduced equipment damage [8]. Te use of compensators such as static synchronous compensators (STAT-COMs) has shown promising results in voltage balancing in three-phase power systems [9][10][11]. In the next section, an overview of recent developments and state-of-the-art techniques for voltage balancing in three-phase power systems will be presented.…”
Section: Introductionmentioning
confidence: 99%