2022
DOI: 10.56748/ejse.223113
|View full text |Cite
|
Sign up to set email alerts
|

Location of semi-rigid connections effect on the seismic performance of steel frame structures

Abstract: In design steel frames, combining semi-rigid and rigid connections can result in better structural performance, particularly in seismic locations. In this study, the effects of semi-rigid beam-to-column connections located on the seismic performance of steel frame structures are investigated. The analysis uses six and twelve-story moment resisting steel frames (MRSF) with rigid, semi-rigid, and dual beam-column connections. These frames are designed according to the Egyptian design codes.  Drain-2Dx computer p… Show more