2007
DOI: 10.1159/000110621
|View full text |Cite
|
Sign up to set email alerts
|

Long-Acting Hydrocortisone for Glucocorticoid Replacement Therapy

Abstract: Background: Glucocorticoid (GC) deficiency is a consequence of various disorders that are by themselves rare. Because of this low prevalence, the low cost of GC replacement therapy and the belief that existing outcomes are good, there has been little interest in development of new and improved pharmaceutical products for treatment of GC deficiency. However, GC replacement therapy is complex: diurnal variation of endogenous cortisol must be replicated, GC needs may change during times of physical and psychologi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
1
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 78 publications
0
6
1
1
Order By: Relevance
“…The low level of surveillance for mineralocorticoid deficiency could have resulted in suboptimal treatment of patients with combined mineralocorticoid deficiency, in particular, of those receiving prednisolone. Furthermore, the fludrocortisone treatment rate (27.1%) was significantly lower in this study than in studies from other countries (70% to 90%) [ 7 24 25 ]. Therefore, we recommend active surveillance for mineralocorticoid status at diagnosis.…”
Section: Discussioncontrasting
confidence: 81%
“…The low level of surveillance for mineralocorticoid deficiency could have resulted in suboptimal treatment of patients with combined mineralocorticoid deficiency, in particular, of those receiving prednisolone. Furthermore, the fludrocortisone treatment rate (27.1%) was significantly lower in this study than in studies from other countries (70% to 90%) [ 7 24 25 ]. Therefore, we recommend active surveillance for mineralocorticoid status at diagnosis.…”
Section: Discussioncontrasting
confidence: 81%
“…Third, the high 08.00 am plasma cortisol concentration and its secondary decrease during the 08.00–10.00 am time period observed in healthy volunteers contrasts with the low undetectable baseline plasma cortisol concentration and secondary rise after hydrocortisone intake in patients, resulting in a shift of cortisol AUC between both groups which may hamper the accuracy of their comparative measurements. New formulations of modified-release hydrocortisone tablets may help obtaining a more physiological and stable circadian cortisol profile [ 27 29 ].…”
Section: Discussionmentioning
confidence: 99%
“…We have found it impractical to administer the midday dose to school‐going children, and hence opted for a twice daily hydrocortisone regimen. A long‐acting preparation of hydrocortisone has recently become available, but is not yet available to us 20 …”
Section: Discussionmentioning
confidence: 99%