2021
DOI: 10.1089/end.2020.0469
|View full text |Cite
|
Sign up to set email alerts
|

Long-Term Follow-Up of Yearly Replaced Double Internal Stents for Extrinsic Malignant Ureteral Obstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 22 publications
1
2
0
Order By: Relevance
“…The median time to TUS failure was 7 months, which is slightly longer than other series published recently, which reported a 4-month median time to failure [ 31 , 32 ]. Median survival after TUS failure was 8 months, and median follow-up time was 17 months—which is longer than previous series [ 3 , 30 ], yet similar to more recent publications [ 31 , 33 ]. We believe that this indicates the improvement of systemic oncologic treatments for different malignancies in recent years, partially due to emerging novel immunotherapies, prolonging these patients’ life expectancy, and furthermore emphasizing the importance of effective urinary drainage for longer intervals.…”
Section: Discussionsupporting
confidence: 85%
“…The median time to TUS failure was 7 months, which is slightly longer than other series published recently, which reported a 4-month median time to failure [ 31 , 32 ]. Median survival after TUS failure was 8 months, and median follow-up time was 17 months—which is longer than previous series [ 3 , 30 ], yet similar to more recent publications [ 31 , 33 ]. We believe that this indicates the improvement of systemic oncologic treatments for different malignancies in recent years, partially due to emerging novel immunotherapies, prolonging these patients’ life expectancy, and furthermore emphasizing the importance of effective urinary drainage for longer intervals.…”
Section: Discussionsupporting
confidence: 85%
“…In the clinical setting, the question of defining the ideal drainage option for patients with EUO has always been a subject of debate. While some urologists prefer single large diameter stent, 15 others use tandem stents [9][10][11] or metal stents. 16,17 The rationale for using tandem stents has relied on the theoretical advantage of two factorsone is the fact that two stents offer twice the cross-sectional area of single stent lumina, and the second is that a lumen is established that lies between the stents and the ureter wall (as seen in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Few studies have focused on quantitative analysis of the impact of stent size and configuration (single, tandem) on volumetric flow in ureteral stents, whether in vivo, 1 ex vivo, 2 in vitro, 3,4 or in silico, [5][6][7][8] in the context of EUO or occlusion by ureteral stones. Moreover, tandem stent configurations have received particular attention as a potentially significant means to ensure drainage in the presence of EUO, [9][10][11] yet discussion continues over the preferred use of single or tandem configurations.…”
Section: Introductionmentioning