Long-Term Measurement of PM2.5 Mass Concentration Using an Electrostatic Particle Concentrator-Based Quartz Crystal Microbalance Integrated With Carbon Dioxide Aerosol Jets for PM Sensing in Remote Areas

Abstract: Fine particulate matter (PM2.5) is a major environmental health risk. Several instruments based on the quartz crystal microbalance (QCM) have been developed for PM2.5 measurement because of their accurate, sensitive, real-time, and low-cost mass measurements. However, prolonged or non-uniform deposition on the quartz crystal can cause nonlinear responses between frequency shifts and mass deposition, and its frequent manual cleaning with wet sponges is required. These disable long-term measurements of the instr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 41 publications
0
2
0
Order By: Relevance
“…This method naturally has limitations in online applications. Currently, there are analyzers based on a Quartz Crystal Microbalance (QCM) [36], which is a thin layer of quartz crystal less than 1 mm thick. Gold films deposited on both sides of the quartz layer serve as electrodes, through which oscillations pass with a frequency typical of quartz.…”
Section: Limitations Of Different Air Pollution Monitoring Technologi...mentioning
confidence: 99%
“…This method naturally has limitations in online applications. Currently, there are analyzers based on a Quartz Crystal Microbalance (QCM) [36], which is a thin layer of quartz crystal less than 1 mm thick. Gold films deposited on both sides of the quartz layer serve as electrodes, through which oscillations pass with a frequency typical of quartz.…”
Section: Limitations Of Different Air Pollution Monitoring Technologi...mentioning
confidence: 99%
“…In addition, as it uses a radiometric source to emit β particles, it is expensive and bulky. In comparison with the above methods, acoustic sensing technology, e.g., using a QCM sensor, has the advantages of low cost, real-time measurement, compact size, and easy acquisition. Another important advantage of using QCM sensing is that it can directly convert the PM mass to the sensor frequency shift. Moreover, the QCM has a relatively low temperature coefficient of frequency (TCF), , leading to good thermal stability for precision sensing applications.…”
Section: Introductionmentioning
confidence: 99%