Long-term performance of a gas chromatography/tandem mass spectrometry assay for tebufelone in plasma

Abstract: An automated gas chromatography/tandem mass spectrometry (GC/MS/MS) based method for the rapid determination of tebufelone (TE) in animal and human plasma has been routinely applied in our laboratory to more than 3000 samples over a 2-year period. The selectivity of MS/MS conducted on a triple quadrupole instrument, combined with the use of a stable-isotope-labeled internal standard, results in excellent analytical figures of merit, as well as minimal sample preparation, rapid analysis, and high assay reliabil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

1992
1992
2000
2000

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 22 publications
0
10
0
Order By: Relevance
“…Human plasma and clinical samples (HIV negative) were obtained within Miami Valley Laboratories and were handled with universal precautions. The extraction procedure was previously validated for a clinical assay based on triple quadrupole MS/MS, which has been fully discussed by Dobson et al [13). To obtain a calibration line from plasma, 1-g samples were spiked with 10 ILL aliquots of TE and the internal standard, as described above (n = 3).…”
Section: Methodsmentioning
confidence: 99%
“…Human plasma and clinical samples (HIV negative) were obtained within Miami Valley Laboratories and were handled with universal precautions. The extraction procedure was previously validated for a clinical assay based on triple quadrupole MS/MS, which has been fully discussed by Dobson et al [13). To obtain a calibration line from plasma, 1-g samples were spiked with 10 ILL aliquots of TE and the internal standard, as described above (n = 3).…”
Section: Methodsmentioning
confidence: 99%
“…In the SIM mode, a quantification limit of 600 fmol per injection could be achieved for the three compounds. An automated GC-tandem MS for determining tebufelone (TE), an anti-inflammatory candidate, and its 13 C, 18 O labeled (TE-CO) analog was developed by Dobson et al (1994). The stable-isotope-labeled TE was used as an in vivo IS to determine the oral administration absolute bioavailability.…”
Section: Ms As a Detector For Gc Hplc And Ce Gc-msmentioning
confidence: 99%
“…Tandem (ie multi-stage) MS is a frequently used technique for identification, structural elucidation of an unknown and to improve the selectivity of quantitative analyses (De Jong et al, 1989;Dobson et al, 1994;Kemp et al, 1995;Schweer et al, 1996). The majority of tandem MS is performed with triple quadropole where the first acts as a mass selective filter for the parent ion which is then further fragmented by a collision gas such as argon in the second quadropole.…”
Section: Ms As a Detector For Gc Hplc And Ce Gc-msmentioning
confidence: 99%
“…Determination was carried by capillary GC/ECD and GC/MS/MS. Both chromatographic methods were developed taking into account the criteria established for the validation of routine quantitative analytical compounds 26–28. The limitations and advantages of using GC/ECD or GC/MS/MS techniques for quantitative and qualitative analyses of serum samples are compared and discussed.…”
Section: Introductionmentioning
confidence: 99%