2012
DOI: 10.1016/j.ajic.2011.11.020
|View full text |Cite
|
Sign up to set email alerts
|

Long-term survival curve of methicillin-resistant Staphylococcus aureus on clinical contact surfaces in natural-like conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
2
1

Relationship

2
8

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 12 publications
0
7
0
1
Order By: Relevance
“…Therefore, the immediate effectiveness of the experimental protocol was not measured. It is possible that organisms detected after three-months were not eradicated at baseline since S. aureus can exhibit long-term survival on surfaces (63, 64). However, host recolonization and replenishment of the environment over time is also possible.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, the immediate effectiveness of the experimental protocol was not measured. It is possible that organisms detected after three-months were not eradicated at baseline since S. aureus can exhibit long-term survival on surfaces (63, 64). However, host recolonization and replenishment of the environment over time is also possible.…”
Section: Discussionmentioning
confidence: 99%
“…After treating the patients under a revised IC protocols, including single use of barrier covers, MRSA was not detected on the surfaces of the dental operatory, and no HAI occurred during hospitalization. MRSA long-term persistence in a simulation of dental operative conditions up to 4 months suggests that the risk for MRSA diffusion on CCSs is high in the dental office [90]. In fact, hydrophobic microorganisms adhere relatively easily to medical devices and CCSs constructed from hydrophobic materials (rubber, silicon, stainless steel, teflon, etc.…”
Section: Environmental Contamination In Dental Settingmentioning
confidence: 99%
“…In the ICU, it's required that HCWs should wash and clean hands before and after contact with each patient, since each HCW spent 27 min with each patient per visit, so the required hand cleaning frequency was about 4.4 times per hour during healthcare visit. However the compliance with hand hygiene is poor [29,30]. We assumed HCWs would clean their hands after 42% of healthcare visits with patients, which is the average hand hygiene compliance rate observed in 12 studies conducted in ICUs (Additional file 1: Part A.…”
Section: Model Interventionmentioning
confidence: 99%