2000
DOI: 10.1164/ajrccm.161.4.9905040
|View full text |Cite
|
Sign up to set email alerts
|

Longitudinal Follow-up Study of Smoking-induced Lung Density Changes by High-resolution Computed Tomography

Abstract: To evaluate the ability of high-resolution computed tomography (HRCT) to detect longitudinal changes in structural abnormalities caused by smoking, HRCT and pulmonary function tests were used to examine nonsmokers, current smokers, and past smokers annually for 5 yr. Inspiratory HRCT was taken for the upper, middle, and lower lung fields, while expiratory images were obtained for the upper and lower lung fields only. We estimated the three quantitative CT parameters including MLD (mean CT value), HIST (CT valu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

17
84
2
1

Year Published

2005
2005
2020
2020

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 134 publications
(104 citation statements)
references
References 27 publications
17
84
2
1
Order By: Relevance
“…A few examples of such studies are: [32], [37]- [40]. In this paper, we have performed a similar evaluation and correlated the proposed quantitative measures with another marker for emphysema in Section III-E, namely, % , and in general the correlations were strong, up to .…”
Section: Discussionmentioning
confidence: 82%
“…A few examples of such studies are: [32], [37]- [40]. In this paper, we have performed a similar evaluation and correlated the proposed quantitative measures with another marker for emphysema in Section III-E, namely, % , and in general the correlations were strong, up to .…”
Section: Discussionmentioning
confidence: 82%
“…Lung density varies between individuals, especially in cases of respiratory disease. Even for healthy patients, lung density and corresponding attenuation values depend on respiratory and body position (24), age, or smoking habits (25).…”
Section: Discussionmentioning
confidence: 99%
“…Using clinical meaningful detectable change in lung density metrics (i.e. detectable based on current scanner resolution and a reasonable sample size of few hundred subjects) from published literature(1416) and results of our repeatability analysis, we extrapolated to the number of subjects needed to achieve at least 80% power to detect a typical change in lung density metrics over a short period of time. For the low attenuation area variables that we considered (%LAA856, %LAA910, and %LAA950), the power analyses utilized relative percent difference between repeat scans.…”
Section: Methodsmentioning
confidence: 99%