2019
DOI: 10.1111/mve.12366
|View full text |Cite
|
Sign up to set email alerts
|

Loop‐mediated isothermal amplification (LAMP) for the identification of invasive Aedes mosquito species

Abstract: Invasive Aedes mosquito species (Diptera: Culicidae) are of public health concern in Europe because they are either recognized or potential vectors of pathogens. Loop‐mediated isothermal amplification (LAMP) is a rapid and simple method for amplifying DNA with high specificity and efficiency, with the technique having potential for application in the field, including in high‐throughput format. Specific LAMP assays based on rDNA internal transcribed spacers 1 or 2 sequences, considering intraspecies variability… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(23 citation statements)
references
References 39 publications
0
23
0
Order By: Relevance
“…A heating block or water bath can be battery-powered for locations where electrical mains power is not available. Test results are obtained by visual inspection, without the need for gel-based or cell phone visualization [16,22]. Critically, LAMP assays are cheap, being priced at < $US3.00 per test, which is considerably lower than the � $US20 per test required to extract and perform a real-time TaqMan PCR.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…A heating block or water bath can be battery-powered for locations where electrical mains power is not available. Test results are obtained by visual inspection, without the need for gel-based or cell phone visualization [16,22]. Critically, LAMP assays are cheap, being priced at < $US3.00 per test, which is considerably lower than the � $US20 per test required to extract and perform a real-time TaqMan PCR.…”
Section: Discussionmentioning
confidence: 99%
“…Primers for the detection of Ae. aegypti (Table 1) were targeted to the ITS1 ribosomal spacer region [16]. Primers for the detection of Ae albopictus were designed targeting the ITS1 region using previously described LAMP assay parameters [18].…”
Section: Colorimetric Lamp Assaymentioning
confidence: 99%
See 2 more Smart Citations
“…LAMP primers for the Ae. aegypti ITS1 gene were taken from Schenkel et al (24). Primers were manufactured according to our specifications by Reactions were incubated at 65°C for 20-30 minutes.…”
Section: Lamp Assaysmentioning
confidence: 99%