“…Thus, if loudness is a contributing factor to the negative effects of higher presentation level on ratings of valence reported by Picou (2016) , an individualized hearing aid fitting might expand the range of valence ratings for participants with hearing loss. Indeed, in the study of Buono et al (2021) , the unfiltered stimuli were perceived as louder than the filtered stimuli, yet pleasant stimuli were rated as more pleasant, and unpleasant stimuli were rated as more unpleasant in the unfiltered condition. These results suggest that, by amplifying only specific frequencies, rather than by amplifying all frequencies equally, hearing aids might ameliorate the effects of hearing loss on experienced emotion, resulting in ratings of valence with a wider range relative to ratings without hearing aids.…”