“…In CT, a variation of the tube voltage with projection angle is undesirable since the attenuation values will change when the beam energy changes; inconsistent measurements of attenuation and, in consequence, image artefacts would result. Therefore FD-CT is generally carried out with fixed voltage as is the case in clinical CT; automatic exposure control (AEC) modulates the tube current only and aims to achieve constant detector entrance dose over the scan range [13,14].…”
Section: Technology Of C-arm Fd-ct Systemsmentioning
confidence: 99%
“…In CT, a variation of the tube voltage with projection angle is undesirable since the attenuation values will change when the beam energy changes; inconsistent measurements of attenuation and, in consequence, image artefacts would result. Therefore FD-CT is generally carried out with fixed voltage as is the case in clinical CT; automatic exposure control (AEC) modulates the tube current only and aims to achieve constant detector entrance dose over the scan range [13,14].…”
Section: Technology Of C-arm Fd-ct Systemsmentioning
confidence: 99%
“…[11][12][13] Although currently available C-arm CT lacks the temporal resolution to assess cerebral blood flow (CBF) or mean transit time, it does provide spatial resolution and contrast sensitivity that should be adequate to measure levels of blood in brain parenchyma (ie, CBV). [14][15][16] Our purpose was to test the hypothesis that in normal canines, CBV could be measured by using C-arm CT and that these measurements would correlate with those made by using PCT.…”
mentioning
confidence: 99%
“…Although scatter can be reduced by using narrow collimation, this may not be clinically practical if the location of the lesion is not known a priori. The correction approach implemented here estimates the primary radiation from the projection data by using an iterative method involving a multiplicative correction step, 19 and further improvements by using iterative techniques, hardware approaches, or a combination of the 2 are possible. [20][21][22][23][24][25][26][27][28][29][30] The number of views taken over a partial-circle scan can also be a limiting factor for image quality if insufficient angular sampling (ie, too large an angle between views) occurs.…”