Abstract: Recently, there has been a substantial increase in the availability and use of low-cost particulate matter sensors in a wide range of air quality applications. They carry the promise of revolutionising air quality monitoring, yet considerable reservations exist regarding their performance and capabilities, thus hindering the broader-scale utilization of these devices. In order to address these concerns and assess their feasibility and accuracy for various applications, we evaluated six low-cost PM 2.5 sensors … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
40
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 48 publications
(42 citation statements)
references
References 38 publications
2
40
0
Order By: Relevance
“…All sensors exhibited a high bias, consistent with other field evaluations of the PA [ 7 , 16 , 21 , 29 , 30 ] and other optical-based sensors [ 8 , 15 , 16 , 19 ]. Additionally, the sensors evaluated here had higher correlations to the reference than most field studies using optical-based sensors (0.3 < r 2 < 0.95) [ 10 ].…”
Section: Resultssupporting
confidence: 86%
See 3 more Smart Citations
“…All sensors exhibited a high bias, consistent with other field evaluations of the PA [ 7 , 16 , 21 , 29 , 30 ] and other optical-based sensors [ 8 , 15 , 16 , 19 ]. Additionally, the sensors evaluated here had higher correlations to the reference than most field studies using optical-based sensors (0.3 < r 2 < 0.95) [ 10 ].…”
Section: Resultssupporting
confidence: 86%
“…This was likely due to the much higher PM concentrations encountered near fires, where many more hourly averages are above the lower detection limits of both the sensors and the reference instruments [ 21 ]. Sensor performance during smoke impacted times was more similar to the high correlations observed in laboratory evaluations, where the concentration range is much larger and aerosol characteristics are roughly constant [ 14 , 16 , 19 ]. The sensors evaluated here also exhibited a linear response up to the very unhealthy AQI level (150.5–250.5 µg/m 3 ), meaning that with a simple linear correction these sensors may be useful for identifying appropriate health guidance during wildfires.…”
Section: Resultssupporting
confidence: 60%
See 2 more Smart Citations
“…chemistry) and humidity, and research findings suggest that a rigorous calibration with "tailored" aerosols, i.e. aerosols representative of the environment of their intended use, is needed (Jayaratne et al, 2020;McNamara et al, 2011).…”
Section: Introductionmentioning