2011
DOI: 10.1016/j.sna.2011.03.048
|View full text |Cite
|
Sign up to set email alerts
|

Low-firing thick-film piezoresistive sensors for medical instruments

Abstract: In this work, a low-firing thick-film materials system allowing fabrication of piezoresistive sensors on surgical alloys is presented in detail, with application to a force-sensing surgical instrument. The system comprises a series of individual thickfilm dielectric, conductor, resistive and overglaze compositions based on a lead borosilicate glass matrix. The moderate achieved firing temperature, around 625°C, greatly increases compatibility with metallic substrates, allowing the use of high-strength medical … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…Moreover additional reducing conditions may be generated, on alloys forming Cr 2 ), and that are moreover not deleterious when fully reduced to metal; Co is in fact found in dielectrics for steel substrates ( Table 5). As the situation is very similar to PbO, it is surmised that our previous experiments with Pb based glasses, where Fe 2 O 3 additions were successfully applied, 68,71 may be extended to Bi based ones. It must be mentioned no adhesion problems were encountered on Al alloys, 445 in spite of the very strong reducing power of Al; it is surmised that formation of Al 2 O 3 rapidly results in the effective stoppage of oxygen diffusion, and hence limited interaction with the substrate, a hypothesis supported by the absence of oxidoreduction buffers in commercial enamels for Al.…”
Section: Dielectrics On Metal Substratesmentioning
confidence: 80%
See 1 more Smart Citation
“…Moreover additional reducing conditions may be generated, on alloys forming Cr 2 ), and that are moreover not deleterious when fully reduced to metal; Co is in fact found in dielectrics for steel substrates ( Table 5). As the situation is very similar to PbO, it is surmised that our previous experiments with Pb based glasses, where Fe 2 O 3 additions were successfully applied, 68,71 may be extended to Bi based ones. It must be mentioned no adhesion problems were encountered on Al alloys, 445 in spite of the very strong reducing power of Al; it is surmised that formation of Al 2 O 3 rapidly results in the effective stoppage of oxygen diffusion, and hence limited interaction with the substrate, a hypothesis supported by the absence of oxidoreduction buffers in commercial enamels for Al.…”
Section: Dielectrics On Metal Substratesmentioning
confidence: 80%
“…71,323 Typical configurations are multilayer circuits and crossovers (Fig. 8c), as well as the deposition of complete circuits on metal (D).…”
Section: Insulating Dielectricsmentioning
confidence: 99%
“…Among others, it is possible to release the area on the surface of outer layer of the PCB for assembly of active elements (Stęplewski and Borecki, 2013). Additionally, thanks to the piezoresistive effect, the thick-film resistors can be applicable as sensors of force, torque, load, acceleration or pressure (Jacq et al , 2014; Jacqa et al , 2013; Maeder et al , 2011; Serra et al , 2012; Papakostas and White, 2000; Gutierrez and Meng, 2010; White, 2017; Maeder et al , 2004).…”
Section: Introductionmentioning
confidence: 99%
“…Tactile sensors have been added to surgical tools for real-time haptic feedback [10][11][12]. Force sensors combined with endoscopes have been utilized to monitor contact to protect nearby soft tissues [13][14][15].…”
Section: Introductionmentioning
confidence: 99%