2019
DOI: 10.1007/s00604-019-3340-x
|View full text |Cite
|
Sign up to set email alerts
|

Low fouling electrochemical sensing in complex biological media by using the ionic liquid-doped conducting polymer PEDOT: application to voltammetric determination of dopamine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(16 citation statements)
references
References 49 publications
1
15
0
Order By: Relevance
“…Hence, pH = 7.0 was selected as the optimal pH for the oxidation of DA at the ERGNRs/SPCE surface. This value is similar to the values affirmed in some studies for DA electrooxidation at the surface of different chemically modified electrodes (Table 1) [38][39][40][41][42][43]. Figure 2 shows cyclic voltammetric curves of a 100.0 μM DA (Figure 2(a)) and a 75.0 μM of UA (Figure 2(b)) obtained by the ERGNRs/SPCE (Curve (B)) and an unmodified SPCE (Curve (A)).…”
Section: Electrochemical Characterization Of Ergnrs/spcesupporting
confidence: 87%
“…Hence, pH = 7.0 was selected as the optimal pH for the oxidation of DA at the ERGNRs/SPCE surface. This value is similar to the values affirmed in some studies for DA electrooxidation at the surface of different chemically modified electrodes (Table 1) [38][39][40][41][42][43]. Figure 2 shows cyclic voltammetric curves of a 100.0 μM DA (Figure 2(a)) and a 75.0 μM of UA (Figure 2(b)) obtained by the ERGNRs/SPCE (Curve (B)) and an unmodified SPCE (Curve (A)).…”
Section: Electrochemical Characterization Of Ergnrs/spcesupporting
confidence: 87%
“…The analytes that these electrochemical sensors aim to detect range from biomarkers to therapeutics to omnipresent organic molecules. [ 219 , 220 , 221 , 222 , 223 , 224 , 225 , 226 , 227 , 228 , 229 , 230 , 231 , 232 , 233 , 234 , 235 , 236 ] As mentioned previously, imidazolium and cholinium‐based ionic liquids have been widely used in biomedicine, which holds true for biosensors. Choline dihydrogen phosphate and 1‐butyl‐3‐methylimidazolium tetrafluoroborate (BMIM[BF 4 ]) coated electrodes with immobilized antibodies were used to detect cortisol and interleukin‐6 in human sweat.…”
Section: Biomedical Applicationsmentioning
confidence: 99%
“…Simultaneous detection gave LOD values of 50 nM (UA), 20 nM (DA), and 1.0 µM (AA) in PBS solution at pH 6. Poly (3,4-ethylenedioxythiophene) doped with ionic liquid (1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide) on glassy carbon electrode (PEDOT/IL/GCE) has been also used as biofouling resistant DA electrode showing porous microstructure, high electrical conductivity, and good stability [ 117 ]. LOD and linear range values of 33 nM and 0.2 μM to 328 μM, respectively, were found for DA sensing in presence of proteins such as bovine serum albumin (BSA), human serum albumin (HSA), and chicken egg white lysozyme (LZM).…”
Section: Electrochemical Sensors Based On Conducting Polymersmentioning
confidence: 99%