2004
DOI: 10.1007/s00402-004-0745-7
|View full text |Cite
|
Sign up to set email alerts
|

Low-severity metacarpal and phalangeal fractures treated with miniature plates and screws

Abstract: These very favourable results suggest that miniature plates and screws are a possible choice in the treatment of these fractures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
32
1
4

Year Published

2013
2013
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 59 publications
(41 citation statements)
references
References 21 publications
4
32
1
4
Order By: Relevance
“…(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32) A study by Souer et al (33) showed good functional outcome by total active motion more than 230 0 in 18 of 19 patients for whom plate fixation was done in closed unstable metacarpal fractures. Another study by Gupta et al (11) showed excellent functional outcome with total active movements more than 230 0 in all of his patients of unstable metacarpal fractures treated with plate fixation.…”
Section: Discussionmentioning
confidence: 99%
“…(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32) A study by Souer et al (33) showed good functional outcome by total active motion more than 230 0 in 18 of 19 patients for whom plate fixation was done in closed unstable metacarpal fractures. Another study by Gupta et al (11) showed excellent functional outcome with total active movements more than 230 0 in all of his patients of unstable metacarpal fractures treated with plate fixation.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, these procedures are costly, require special equipment (24,28) and may not necessarily improve power recovery beyond what is achieved using a conservative approach. In a review of 45 metacarpal fractures stabilized via ORIF using miniature plates or screws, Trevisan et al (28) reported a mean grip strength reduction of 3.2±10.1%, which remained stable at two years postfracture; furthermore, a 31.1% complication rate resulted. Westbrook et al (13) noted no significant difference in grip strength measurements following little finger metacarpal shaft fractures that were either treated with ORIF via plate or K-wire fixation, or conservatively with no attempt at reduction.…”
Section: Figure 1) X-rays Revealing Displacement In 12 Of the 13 Patimentioning
confidence: 99%
“…The results obtained from the current study support others in the literature (9,10,16) that demonstrate that the loss of metacarpal length associated with these fractures is limited to a degree of shortening that is not consistent with power deficits sufficiently large to significantly affect functional recovery in the hand. Furthermore, a review of grip strength outcomes following various approaches to internal fixation has revealed results similar to those obtained via conservative techniques (13,16,28). A properly performed prospective randomized controlled trial of conservative versus surgical management outcome on power is warranted.…”
Section: Figure 1) X-rays Revealing Displacement In 12 Of the 13 Patimentioning
confidence: 99%
See 1 more Smart Citation
“…Implantate (z. B. VariAx™ Hand, Profyle Hand und Kombimodule der Firma Stryker®, Aptus® Hand oder winkelstabile Handminiplatten der Firma Königsee-Implantate®) zur Verfügung stehen [3,17,19]. Wir verwenden an unserer Klinik das oben genannte Implantat aus logistischen bzw.…”
unclassified