2006
DOI: 10.1063/1.2222085
|View full text |Cite
|
Sign up to set email alerts
|

Low temperature cell for cavity ring down absorption studies

Abstract: A rigid, monolithic but still scannable cavity ring-down spectroscopy cell Rev. Sci. Instrum. 83, 043115 (2012); 10.1063/1.3700978Ab initio calculations of low-lying electronic states of vinyl chloride Phase shift cavity ring down is a technique that due to its long optical path length is an ideal method to detect weak absorptions. Coupling the method to a custom fitted cryostat allows gas phase molecules to be studied at cryogenic temperatures in a thermally isolated vacuum chamber. A novel design is describe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2009
2009
2025
2025

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 53 publications
0
12
0
Order By: Relevance
“…The advantage of the phase shift technique is that no signal averaging is necessary and the spectra can be obtained in a very short time. We have shown 12 that if the laser bandwidth is smaller than the absorption band, the measured cross sections are as good as the ones obtained with conventional absorption techniques. In this investigation the absorption bands are obtained at different pressures and the integrated bands are plotted versus the density of the gas sample to obtain the experimental cross section to be compared with theoretical calculations.…”
Section: Methodsmentioning
confidence: 56%
“…The advantage of the phase shift technique is that no signal averaging is necessary and the spectra can be obtained in a very short time. We have shown 12 that if the laser bandwidth is smaller than the absorption band, the measured cross sections are as good as the ones obtained with conventional absorption techniques. In this investigation the absorption bands are obtained at different pressures and the integrated bands are plotted versus the density of the gas sample to obtain the experimental cross section to be compared with theoretical calculations.…”
Section: Methodsmentioning
confidence: 56%
“…The spectra were taken at 295 K. The experimental set up for the PS-CRD technique has been given in previous publications. 16,17 In this technique two different lasers are used in the range between 12 200 and 14 300 cm −1 (Ti:sapphire) or in the range from 14 800 to 16 700 cm −1 (dye laser). The modulated excitation laser beam passes through the optical cavity and is detected with a photomultiplier.…”
Section: Methodsmentioning
confidence: 99%
“…Experimental details of our technique, cryostat, and low temperature optical cavity have been given in previous publications [1][2][3]. Figure 1 (top) summarizes the main components of the low temperature optical cavity.…”
Section: Methodsmentioning
confidence: 99%
“…With our experimental set up, CRD is performed with a variable temperature (77-297 K) cavity [3,4]. Our cavity design is such that the complete optical cavity including the mirrors is in a vacuum chamber at the temperature of the cold head of the cryostat.…”
Section: Introductionmentioning