2018
DOI: 10.1063/1.5036904
|View full text |Cite
|
Sign up to set email alerts
|

Low temperature growth of ZnO nanorods array via solution-immersion on TiO2 seed layer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The tip on the syringe pump was connected to a high voltage positive terminal at varying distances (3, 4, 5, 6, 7, and 8 cm) located horizontally relative to the collector plate of the fluorine-doped tin oxide glass deposited with TiO 2 with negative terminals using the direct deposition method. The flow rate of the solution through the needle was varied (3,4,5,6,7, and 8 μL/min) based on the rate at the electrospinning machine. The fluorine-doped tin oxide glass deposited with TiO 2 nanoparticles and ZnO nanofibers was sintered at a temperature of 500 °C with a retention time of 1 h using a Digital Muffle Furnace model XD-1700M.…”
Section: Fabrication Of Zno Nanofibersmentioning
confidence: 99%
See 2 more Smart Citations
“…The tip on the syringe pump was connected to a high voltage positive terminal at varying distances (3, 4, 5, 6, 7, and 8 cm) located horizontally relative to the collector plate of the fluorine-doped tin oxide glass deposited with TiO 2 with negative terminals using the direct deposition method. The flow rate of the solution through the needle was varied (3,4,5,6,7, and 8 μL/min) based on the rate at the electrospinning machine. The fluorine-doped tin oxide glass deposited with TiO 2 nanoparticles and ZnO nanofibers was sintered at a temperature of 500 °C with a retention time of 1 h using a Digital Muffle Furnace model XD-1700M.…”
Section: Fabrication Of Zno Nanofibersmentioning
confidence: 99%
“…DSSCs performance was examined using scanning electron microscopy (SEM) to determine the morphology and size of semiconductor nanofibers; absorbance testing with a UV 1800 UV-VIS spectrophotometer was used to measure the bandgap energy value using Tauc's plot method, as shown in Equation 1 (Alrikabi, 2017;Firdaus et al, 2012). The bandgap energy function is the value of VOC, as shown in Equation 2 (Bakr et al, 2019); the dyeloading ability of each sample was measured using the desorption method and the Lambert-Beer equation, which tests the solution's absorbance, as shown in Equation 3 (Asib et al, 2018).…”
Section: Testingmentioning
confidence: 99%
See 1 more Smart Citation