LPV Control of Current Source Inverter synchronized with the grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…R c and R L are generally large, and the losses caused are relatively low, which are easy to be ignored; however, this part of passive damping has a great influence on current gain and damping. The current loop transfer function G i (s) and equivalent impedance Z g (s) of the CL filter are further equivalent in Equations ( 15) and (16). Passive damping has increased but remains underdamped.…”
Section: Filter Modeling and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…R c and R L are generally large, and the losses caused are relatively low, which are easy to be ignored; however, this part of passive damping has a great influence on current gain and damping. The current loop transfer function G i (s) and equivalent impedance Z g (s) of the CL filter are further equivalent in Equations ( 15) and (16). Passive damping has increased but remains underdamped.…”
Section: Filter Modeling and Analysismentioning
confidence: 99%
“…Energies 2022, 15, 4219 2 of 16 The CSI is different from the VSI and requires a capacitive filter to achieve lateral commutation; however, the CL has inherent resonance and underdamping problems, which easily cause system oscillation. In practice, the equivalent grid impedance at the point of common coupling may change rapidly and widely so that the bandwidth and stability margin are very narrow, which may cause the distortion and oscillation of the grid-connected current.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To reduce the current harmonics, Poon et al introduced a new control method of carrier phase-shift for distribution of the power system [23]. Ghersin et al presented a linear change control strategy for the inverter, which promotes the output power quality of the inverter, substantially reducing the total harmonic distortion (THD) of current [24]. Prasad et al present the inverter circuit of thirteen levels for green power, thus improving effective power, then reducing THD [25].…”
Section: Introductionmentioning